You are on page 1of 36

www.mrslim.

com
Mr. Slim® Split-ductless Systems: Redefining Comfort
Comfort is a concept many of
us notice only when we’re
either uncomfortable or very
relaxed. But at Mitsubishi
Electric HVAC Advanced
Products Division, all we
think about is comfort. Our
industry-leading Mr. Slim
split-ductless cooling and
heating systems reflect this
thinking. At home or at work
our Mr. Slim systems are
designed to make any space
inviting and comfortable.

Maybe your home has a room


that’s always too hot or too
cold. Or, perhaps, you’re
looking for a way to control
the climate effectively in
multiple rooms in your office
building such as in conference
rooms. No matter what your
cooling and heating needs
may be, Mr. Slim systems
are the perfect way to
transform your home or
workplace into a tranquil
and productive environment.

02
Good for the environment and your bottom line.
• Eco-friendly refrigerant: Environmentally-friendly R410A refrigerant offers zero Ozone Depletion
Potential (ODP) and allows for higher heat transfer coefficient (COP). This innovative feature means a
reduction in equipment size, a reduction in piping size and higher pressure for greater performance.
Smaller equipment also means less impact on the environment at the end of the product’s life cycle.
• Standard compliance: All Mitsubishi Electric HVAC products follow standards and guidelines as set
forth by the Energy Star, EPA, ARI, UL, ASHRAE, ETL and ISO.
• Recycling design: Our air conditioners are specially designed to allow for easy cleaning, efficient
disassembly and more practical recycling. The number of parts used in indoor units has been reduced
by adopting modular components, a process which also simplifies materials separation for recycling.
To date as much as 84 percent of the materials used to build a Mr. Slim system is recyclable.
• Smart energy usage: Mitsubishi Electric INVERTER zoning systems smartly deliver only the amount
of capacity needed unlike a typical full-power ON system. Individual indoor air handlers are installed
within the zone. These air handlers measure the load for that specific zone and deliver for added
efficiency only the capacity needed directly to the space, as compared to energy lost in long duct
runs. If the zone is not being used, you do not have to condition the space. Smarter sensing
technology and microprocessors enhance the system’s ability to measure room temperature
accurately for added comfort, performance and efficiency.
• Minimal impact on landfills: All air-conditioning products use long-life washable filters.

What is Mr. Slim Why Mr. Slim Systems?


Split-ductless Technology? Mitsubishi Electric is without exception the industry
For decades split-ductless air-conditioning and heat leader in split-ductless air-conditioning technology.
pump systems have been the primary solution for Our innovations have defined cutting-edge technol-
cooling and heating interior spaces around the world. ogy for over 28 years. Compare, and you’ll see that
Our quiet and powerful Mr. Slim systems have three no one surpasses the Mr. Slim brand’s performance
main components: an indoor unit, an outdoor unit for quiet, easy-to-use and energy-efficient operation.
and a remote controller. Installation is as simple as And because our split-ductless technology carries the
mounting the indoor and outdoor units, connect- Mitsubishi Electric name, you know every product
ing the refrigerant lines and making a few electrical is built to last. The bottom line is Mr. Slim systems
connections. An easy installation for your authorized deliver the ultimate in comfort control for your home
contractor means you will be quickly enjoying the or office. It’s true today and will be comfortably
comfort Mr. Slim systems provide. evident for years to come.

03
Where Can Mr. Slim Products Be Used?
Mr. Slim split-ductless systems are specifically designed to improve the
comfort level in an uncomfortably hot or cold room of an existing building.
Because Mr. Slim Systems do not require ductwork, they are the perfect
cooling and heating systems for renovating older buildings – even those with
plaster walls and brick facades that were constructed before air conditioning
was available. The versatility and variety of applications for Mr. Slim systems
are virtually unlimited. They’re an excellent choice for almost any spot-cooling
or heating situation, including enclosed sunrooms, upstairs bedrooms,
new additions, bonus rooms, finished basements, classrooms, hospitals,
nursing homes, restaurants, hotels, workout rooms, computer rooms,
offices and churches.

Mr. Slim systems work hard for you even in extreme temperatures, maintaining
a toasty, warm environment even when it’s as cold as -13o F outside with the
Hyper-Heating INVERTER (H2i™) P-Series system. Mr. Slim systems are also
equipped with an anti-allergen filter that helps prevent the circulation of air with
contaminants. And because the indoor units can be controlled by zone, it is
easy to set the controls for the exact room temperature you want within
any given space.

How does it work?


Mr. Slim cooling and heating solutions are perfect for almost any space be-
cause their innovative engineering optimizes the capabilities of the INVERTER
technology and R410A refrigerant for more efficient systems with smaller in-
door and outdoor units. R410A refrigerant is environmentally friendly and does
not deplete the ozone. The systems themselves are also made of recyclable
materials. To find out more about Mr. Slim split-ductless products or to locate
an authorized Diamond Dealer near you, visit www.mrslim.com.

04
G l o ss a r y INDEX
Air conditioner: A mechanical device used to INVERTER TECHNOLOGY: Pages 06-07
control temperature and air movement in a
confined space. M-Series: 9,000-36,000 Btu/h
Btu/h (British Thermal Units per Hour): A measure Residential and Select Commercial Applications
of cooling or heating capacity.

Capacity or Load: A refrigeration rating system Overview of Product Line
usually measured in Btu/h. Pages 08 - 09

Compressor: A refrigeration or air-conditioning Product Lineup and Technology Descriptions


system pump that circulates refrigerant through pipes Pages 10 - 11
between an outdoor and indoor unit using pressure.

Heat pump: An air-conditioning system can reverse MS/MSY Single-zone, Wall-mounTed:


the direction of refrigerant flow to provide either cooling Air Conditioners
or heating to the indoor space. - Specifications
Pages 12 - 13
HSPF (Heating Season Performance Factor): A rating
of the seasonal efficiency of a heat pump unit when
operating in the heating mode. MSZ SINGLE-ZONE, WALL-MOUNTED:
Air Conditioners and Heat Pumps
HVAC: A term which stands for Heating, Ventilation - Specifications
and Air Conditioning. Pages 14 - 15
Indoor unit: The air handler of an air-conditioning
system, which contains a heat exchange coil, MXZ Multi-zone wall-mounted:
filters, remote signal receiver and fan and provides Inverter-driven Multi-zone Heat Pumps
conditioned air into the space. - Specifications
Pages 16 - 17
INVERTER TECHNOLOGY: Mitsubishi Electric’s
m x z m ult i
MUY, MUZ and all P-Series outdoor units use
inverteR-driven compressor technology (Variable MSZ-A09NA (4)
Frequency Drive) to provide exceptional indoor high-
speed cooling and heating. By responding to indoor
and outdoor temperature changes, these systems P-Series: 12,000-42,000 Btu/h
reduce power consumption by varying the compressor
speed for extra energy savings. The system operates Commercial, Institutional and Large Residential
only at the levels needed to maintain a constant and
comfortable indoor environment. Our CITY MULTI® Product Lineup and Technology Descriptions
product line also incorporates inverter technology.
Pages 18 - 19
(Visit www.mrslim.com for details.)

Microprocessor: An electrical component


H2i™ HYPER-HEATING INVERTER:
consisting of integrated circuits, which may accept, Heat Pump System
store, control and output information. - Specifications
Pages 20 - 23
OUTDOOR Unit: A component of an air-conditioning
system which contains compressor, propeller fan, PKA WALL-MOUNTed:
circuit board and heat exchange coil. It pumps Air Conditioners and Heat Pumps
refrigerant to/from indoor unit. - Specifications
Pages 24 - 26
Refrigerant: A gas/liquid substance used to
provide cooling by direct absorption of heat.
PLA ceiling-recessed cassette:
Mitsubishi Electric products use environmentally-
friendly R410A refrigerant.
Air Conditioners and Heat Pumps
- Specifications
Refrigerant lines: Copper tubing through which Pages 27 - 29
refrigerant flows to and from indoor and outdoor units.
PcA ceiling-suspended:
SEER (Seasonal Energy Efficiency Ratio): A rating of Air Conditioners and Heat Pumps
the seasonal efficiency of air-conditioning or heating - Specifications
units in cooling mode. Pages 30 - 32
Split-Ductless System: A system comprised
of a remote outdoor condensing unit connected by
Rating Conditions, Refrigerant tubing
refrigerant pipes to a matching, non-ducted indoor
air handler and a remote controller. Special cases for and Line lengths: Page 33
introducing ventilated air may call for limited ducting
to air handler from outside. Accessories: Page 34 

LINE-HIDE™ and Diamondback™ Ball Valves:


Page 35

05
INVERTER
INVERTER-DRIVEN COMPRESSOR TECHNOLOGY
INVERTER

Inverter Technology for Exceptional High-speed Performance


Year-round Comfort and Performance When You Need It
High rotation compressor speeds cool and heat a room
Certain straight-cool and all heat pump outdoor units use
quickly, saving both energy and cash. The compressor
Mitsubishi Electric’s inverter-driven compressor technology
speed is controlled to maximize efficiency, changing
(Variable Frequency Drive) to provide exceptional, high-speed
speeds according to the cooling and heating load
cooling and heating performance. Thanks to high rotation speeds,
of a room.
desired temperatures are reached more quickly than with
conventional systems so you can enjoy your ideal level
of comfort without delay.

Like a car’s cruise control, the system varies the compressor


speed, which reduces power consumption for extra energy
savings. The system adjusts itself precisely to the level needed to
maintain a consistently comfortable indoor environment. Precise
rotation speed control allows the system to maintain a comfortable,
consistent room temperature.

Neodymium
magnets

INVERTER-driven Compressor
(not shown to scale)

06
INVERTER

Optimum Comfort Year-round Extra Energy Savings


INVERTER-driven systems detect subtle changes in For optimum performance inverter technology delivers only the
temperature and automatically adjust compressor energy needed to satisfy the cooling and heating load in a room
speed unlike conventional units, which start and stop reducing energy consumption. Our City Multi® VRFZ residential
repetitively. Precise rotation speed efficiently maintains and commercial product line also employs INVERTER technology.
desired temperature, reducing temperature swings, and Like Mr. Slim products the City Multi inverter-driven systems
provides a more comfortable climate. give you increased performance capabilities and design flexibility,
making Mitsubishi Electric products the best choice for any of your
cooling and heating applications. Visit www.mehvac.com for more
information about CITY MULTI technology.

MSZ-A12 Indoor Unit

MSZ-A12 Indoor Unit

MXZ Outdoor Unit MSZ-A12 Indoor Unit

Single Outdoor Unit

07
M-Series
residential AND select commercial

Comfort is a home that’s cool and dry in the


summer and cozy and warm in the winter.
This environment is what you get with the
Mr. Slim system: perfect year-round comfort.
The M-Series systems install easily. Mounted
high on the wall, the indoor unit blends into
most room environments without taking up
any window space. These systems also
feature automatic cooling/heating change-
over, which automatically switches the
system between cooling and heating to
compensate for fluctuating temperatures.
They’re nearly silent because their fans
deliver air quietly and continuously with
only a gentle whoosh for constant circulation
and filtration. (This capability is the reason
Mr. Slim systems were the first choice for
thousands of churches, schools and librar-
ies across the U.S.) Our M-Series systems
are the perfect way to cool or heat any room
in your home. M-Series inverter systems
provide high-speed and efficient cooling and
heating performance to keep your home
consistently cozy year-round.

Superior Inverter Total, Healthy Comfort System Control in the


Technology Palm of Your Hand
The Powerful mode is available to
Now you can benefit from technology that cool or heat any desired space quickly by Mr. Slim’s M-Series offers a compre-
outperforms conventional systems with lowering the set temperature in cooling hensive remote controller that controls
Mitsubishi Electric’s Inverter technol- mode or raising the set temperature in heat- temperature, fan speed and more.
ogy. Precise rotation speed control helps ing mode by seven degrees. It increases the Choose from four modes: COOL, HEAT,
you keep temperatures consistent. At high fan speed for 15 minutes. Auto changeover AUTO and DRY. The controller also has
rotation speeds you get faster cooling and maintains consistent temperature in a room a 12-hour ON/OFF timer for one-button
heating. At low rotation speeds the tempera- by automatically sensing whether the space control of your personal comfort. Our
ture is efficiently maintained, and starting needs cooling or heating. For challenging new MSY(Z)-A24/D30/D36NA models
currents are kept at low levels so they do cooling environments, low-ambient tem- add the WIDE VANE button to evenly
not affect other appliances. Pulse Amplitude perature control means our systems perform distribute airflow to a wider angle
Modulation (PAM) keeps efficiency high effectively in cooling mode even when the (150 deg.) from right to left, maintaining
by ensuring that the system effectively external temperatures dip to as low as a comfortable temperature across a wide
uses 98 percent of input power supply. 14 degrees Fahrenheit. Even more important area. The M-Series INVERTER models
you can benefit from our anti-allergen filter. can tie into the P-Series wired controller
No Ductwork Required Using blue enzymes, this filter helps and CITY MULTI® M-NET with adapter
minimize germs, bacteria, and viruses. to give an on-the-wall controller option.
Mr. Slim systems require no ductwork, just
a small, three-inch opening for two refriger-
ant lines and control and power wiring to
Control Technology Warm Air, No Drafts
connect the indoor and outdoor units. This With the new A-Control system the indoor Our hot-start technology provides
feature allows for quicker installation, less unit is powered through the outdoor warmth from the beginning. The fan
mess, and a better-looking and more com- unit. Three polarity sensitive wires plus a increases in speed as the coil is
fortable space. If you are adding on a room, ground conductor run from the outdoor to warmed, reducing drafts so when
you don’t have to tie into an existing system the indoor unit providing both power and you want warm air, you’ll get it.
to steal cool or warm air from other areas in communication. Advanced wireless remote
the home. This advanced technology means control is standard on all M-Series models.
better room control and increased comfort On the INVERTER-driven units, an option
plus greater efficiency. for a wired wall controller is available.

08
M -Seri es M SY(Z)-D30N A M o del Indoor U ni t

Features Benefits
INVERTER Maximizes energy savings by making sure only the energy
Technology needed to cool or heat an area is used.

Installs quickly and easily, having no need for major


No Ductwork
construction and remodeling

 ealizes maximum control and energy efficiency by cooling


R
zone control
and heating only those spaces desired
advanced
microprocessor
Creates a comfortable environment no matter what conditions
controls are outside with our advanced self-monitoring controls

convenient wireless Offers comfort control in the palm of your hand with
remote control our remote controller
washable long-life Improves air quality and saves money by being washable
anti-allergen filters rather than replaceable

auto cool/heat Switches automatically from cooling to heating


changeover
Wi rel es s
environmentally
Uses R410A, an environmentally-friendly refrigerant. M -S eri es
friendly Rem ote
C o ntrol l er

M -Seri es M U Y(Z)-D30N A M o del Outdoor U ni t

More Efficiency, More Capacity Cutting-edge Technology


The M-Series product line now includes the In every aspect of the Mr. Slim system, technology is
MSZ-FD09/12NA model series with the highest ductless utilized to make the units more energy-efficient and
system rating in the industry at 23 SEER while being environmentally friendly while providing innovative
extremely quiet at a low 22dB(A) for the indoor unit. The comfort control. Our technology includes expanded
MSY(Z)-D30/36NA systems bring the largest capacity to filter systems, wide vane airflow, the i-see™ sensor
date for the M-Series at 2.5- and 3-tons respectively. and increased energy-efficiency (in select systems).
For detailed information see the next page. Refer to the next page for more detailed information.

09
M-SERIES WALL-MOUNTED A/C LINEUP
(c ooling only ) NEW Large Capacity

MSY( Z ) -D 3 0 / 3 6 NA
M S Non- INVER TER MSY I N V E RT E R I N V E R T E R A i r C o n d itioners
A ir Cond itione r s Ai r C o n d i t i o n e r s a n d H e a t Pu m ps
M-S e ries Wireless 9, 500 to 12, 000 B tu/ h 1 5 , 0 0 0 t o 3 4 , 6 0 0 Bt u / h 3 0 , 7 0 0 t o 3 4 , 6 0 0 Bt u / h
Re m o te Con troller [ p g. 12] [pgs. 12 - 13] [pgs. 14 - 15]

Multiple Filters for Cleaner, Standard filter system (MS(Y)-D30NA Model Shown)

Healthier Air
Mr. Slim M-Series indoor units use a sophisticated multipart Front Panel
filter system to remove contaminants such as allergens,
viruses and bacteria from the air as it circulates.
Hybrid Catechin
The hybrid catechin filter absorbs odor-causing gases. A pre-filters
blue-enzyme anti-allergen filter reduces germs, bacteria
Blue Enzyme
and viruses and helps trap dust, pollens, mites and Anti-allergen filter
other particles; the filter uses an enzyme catalyst to help
break down the sulfur atom bonds in allergen proteins,
transforming them into non-allergen proteins.

A hybrid-coating process makes the catechin filter


washable and – if properly maintained with monthly
cleanings – effective for more than 10 years.

The MSZ-FD09/12NA indoor units incorporate the M-Series


standard Catechin filter plus two more filters for triple
filtration. The second filter, a Blue-Enzyme filter, is a fibrous
material, and its enzymes render allergens harmless. The
third filter, a Platinum Catalyst Deodorizing filter, that has a
ceramic surface absorption element and uses nanotechnol- enhanced filter system (MSZ-FD09/12NA ModelS)
ogy for high power odor absorption. This combination of
filter types provides a complete air purifying system along
with the ultimate comfort solution. Front Panel

Energy Efficiency
Hybrid Catechin
MSZ-FD09/12NA systems produce the highest ductless
pre-filters
system ratings in the industry at 23 SEER while being
extremely quiet at a low 22dB(A) for the indoor unit. Platinum Catalyst
Deodorizing filter
The increased energy efficiency, up to 35 percent over
standard Mr. Slim M-Series systems and 70 percent Blue Enzyme
over industry standard requirement of 13 SEER, is a Anti-allergen filter
result of a new powerful magnet rotor that allows for
lower current input. With the increased energy
efficiency and SEER ratings the MSZ-FD models
are ENERGY STAR® Tier 2 certified.

High Heat from Low Energy


Even at 17˚ F the MSZ-FD09NA models produce
12,500 Btu/h of heat while the MSZ-FD12NA reaches
to 13,600 Btu/h. All of this while being extremely
energy-efficient.

10
M-SERIES WALL-MOUNTED HEAT PUMP LINEUP
NEW Up to 23 SEER (c ooling a n d h e a t i n g )

MSZ-FD 0 9 / 1 2 N A M SZ I N V E RT E R MX Z Mu l t i -Z o n e
High- Ef f ic ie nc y H e a t Pu m p s I N V E RT E R
INVERTER He a t P ump s 9, 00 0 t o 3 3 , 2 0 0 Bt u / h H e a t Pu m ps
9,0 00 an d 12, 000 B tu/ h [pgs. 14 - 15] 2 0 , 0 0 0 t o 3 6 , 0 0 0 Bt u / h
[pg. 14]
[pgs. 16 - 17]

Excellent Air Distribution i-see™ Sensor (MSZ-FD09/12NA models only)

With the WIDE VANE or SWING mode, The i-see sensor detects the always troublesome regions of
available on the MSY(Z)-A24/D30/36NA, temperature closer to the ceiling and the floor. The i-see sensor
there is an option for seven horizontal airflow also controls the airflow up to a wide 150˚ lateral angle for ultimate
directions that provide 150 degrees of airflow comfort (90˚ angle in cooling mode) by scanning the room and
for greater conditioned air circulation. making adjustments based on the ambient temperature readings.
Through this process the MSZ-FD09/12NA systems achieve superior
cooling/heating performance with extremely efficient operation.

Quiet Operation
Do you hear that? No? You barely hear
Multi-zone Heat Pump
our systems because Mr. Slim indoor units System Attributes
operate with nearly a whisper of sound. A
Multi-zone systems mean that people can enjoy their ideal level of
police siren, for example, has a sound level
comfort no matter where they are in the home. Each zone operates
of 118 decibels; a circular saw produces 107
independently. People in the kitchen, master bedroom or living
decibels of sound. A vacuum cleaner in your
room can all enjoy the temperatures that makes them feel most
home creates 74 decibels of noise. Even a
comfortable.
library environment is at 33 decibels while
a whisper-tone voice produces 35 decibels. If you’re looking for a complete comfort solution for several different
Certain Mr. Slim units operates as low as 22 rooms, the MXZ multi-zone system is the right choice for you. You
decibels in low speed and others range from can use up to 19 different indoor unit combinations so the system
26 to 34 decibels in low speed, all lower than is flexible enough to conform to your particular cooling and heating
a whisper-tone voice. needs with up to four rooms from one outdoor unit.

Did you hear that? We hope you did.


source: Friends of Albuquerque’s Environmental Story (http://www.cabq.gov/aes/s5noise.html)

Lifestyle photo courtesy of


Mitsubishi Digital Electronics America, Inc.
Visit mitsubishitv.com for details.

11
(MS-A12WA Model Shown)

ms/msy COOLING-ONLY
m-Series Specifications
INVERTER
Non-inverter
Indoor Unit MS-A09WA MS-A12WA MSY-A15NA MSY-A17NA
Model Name
Outdoor Unit MU-A09WA MU-A12WA MUY-A15NA MUY-A17NA
Rated Capacity Btu/h 9,500 12,000 15,000 16,200
Capacity Range Btu/h - - 3,100-15,000 3,100-16,200
Cooling *1 Total Input W 870 1,070 1,690 (210-1,690) 2,070 (210-2,070)
Energy Efficiency SEER 13 16
Moisture Removal Pints/h 2.7 3.2 4.7 5.1
Sensible Heat Factor 0.68 0.70 0.65
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 115V *2 1 Phase, 60Hz, 208/230V *2
Indoor - Outdoor L1 N / S1-S2 AC 115V AC 208-230V
Voltage Indoor - Outdoor L2 / S2-S3 AC 115V DC12-24V
Indoor - Remote Controller Wireless Type Wireless Type (Optional Wired Controller: DC12V)
MCA A 1.2 1.0
Fan Motor F.L.A. 0.95 0.76
DRY (CFM) 183-261-335 222-286-406 268-328-381
Airflow (Lo-Med-Hi)
WET (CFM) 162-233-300 198-254-363 240-293-342
Sound Pressure Level
dB(A) 26-32-40 33-38-45 34-40-45 34-40-46
(Lo-Med-Hi)
Indoor Unit External Finish Color Munsell No. 1.0Y 9.2/0.2 Munsell No. 1.0Y 9.2/0.2
W: In. 30-11/16 30-11/16
Dimension Unit D: In. 8-1/4 8-1/4
H: In. 11-3/4 11-3/4
Weight Unit Lbs. 23 23
Field Drainpipe Size O.D. In. 5/8 5/8
MCA A 14 16 14
Max. Fuse Size (Time Delay) A 15 20 15
Fan Motor F.L.A. 0.63 0.93 0.52
Model (Type) Single Rotary DC INVERTER-driven Twin Rotary
Compressor R.L.A. 9.3 10.82 10.1
L.R.A. 47 56 12
Airflow CFM 1,083 1,327 1,249
Outdoor Unit
Refrigerant Control Capillary Tube Linear Expansion Valve
Sound Pressure Level
dB(A) 47 52 50 52
(Cooling) *1
External Finish Color Munsell No. 3Y 7.8/1.1 Munsell No. 3Y 7.8/1.1
W: In. 31-1/2 33-7/16 31-1/2
Dimensions D: In. 11-1/4 11-7/16 11-1/4
H: In. 21-5/8 23-13/16 21-5/8
Weight Lbs. 78 96 88
Remote Controller Type Wireless Remote Wireless Remote (Optional Wired Controller)
Type R410A R410A
Refrigerant Charge Lbs., Oz. 2, 5 3, 1 2, 7
Oil Type (Fl. Oz.) NE022 (10.8) NE022 (15.2)
Gas Side O.D. In. 3/8 1/2 1/2
Liquid Side O.D. 1/4 1/4
Refrigerant Pipe
Height Difference (Max.) Ft. 35 40
Length (Max.) 65 65
Connection Method Indoor/Outdoor Flared/Flared Flared/Flared

NOTES: Test conditions are based on ARI 210/240.


*1 Rating conditions (cooling) - Indoor D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.

LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.

12
(MS-A12WA Model Shown) INVERTER
msy COOLING-ONLY (cont.)
m-Series Specifications

Indoor Unit MSY-A24NA MSY-D30NA MSY-D36NA


Model Name
Outdoor Unit MUY-A24NA MUY-D30NA MUY-D36NA
Rated Capacity Btu/h 22,000 30,700 34,600
Capacity Range Btu/h 4,400-22,000 9,800-30,700 9,800-34,600
Cooling *1 Total Input W 2,880 (290-2,880) 3,380 (620-3,380) 4,240 (620-4,240)
Energy Efficiency SEER 16 15.1
Moisture Removal Pints/h 7.3 9.9 11.9
Sensible Heat Factor 0.63 0.64 0.62
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Indoor - Outdoor S1-S2 AC 208-230V
Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller: DC12V)
MCA A 1.0
Fan Motor F.L.A. 0.76
DRY (CFM) 296-431-568 389-639-848
Airflow (Lo-Med-Hi) *1
WET (CFM) 265-385-508 350-576-763
Sound Pressure Level
dB(A) 34-40-49 32-42-49
(Lo-Med-Hi) *1
Indoor Unit External Finish Color Munsell No. 1.0Y 9.2/0.2
W: In. 43-5/16 46-1/16
Dimension Unit D: In. 10-1/4 11-5/8
H: In. 12-13/16 14-3/8
Weight Unit Lbs. 37 40
Field Drainpipe Size O.D. In. 5/8
MCA A 17 21
MOCP A 20 25
Fan Motor F.L.A. 0.93
Model (Type) DC INVERTER-driven Twin Rotary
Compressor R.L.A. 10.1 16
L.R.A. 16 20
Airflow CFM 1,729 1,941
Outdoor Unit Refrigerant Control Linear Expansion Valve
Sound Pressure Level
dB(A) *1 55
(Cooling) *1
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 33-1/16 33-1/16
Dimensions D: In. 13 13
H: In. 33-7/16 33-7/16
Weight Lbs. 128 126
Remote Controller Type Wireless Remote
Type R410A
Refrigerant Charge Lbs., Oz. 4
Oil Type (Fl. Oz.) NEO22 (15.2) NE022 (29)
Gas Side O.D. 5/8
In.
Liquid Side O.D. 1/4 3/8
Refrigerant Pipe Height Difference (Max.) 50
Ft.
Length (Max.) 100
Connection Method Indoor/Outdoor Flared/Flared

NOTES: Test conditions are based on ARI 210/240.


*1 Rating conditions (cooling) - Indoor D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.

LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.

13
(MSZ-FD12NA Model Shown) INVERTER
MSZ heat pump
m-Series Specifications

Indoor Unit MSZ-A09NA MSZ-FD09NA MSZ-A12NA MSZ-FD12NA


Model Name
Outdoor Unit MUZ-A09NA MUZ-FD09NA MUZ-A12NA MUZ-FD12NA
Rated Capacity Btu/h 9,000 9,000 12,000 12,000
Capacity Range Btu/h 5,500-9,000 2,800-9,000 5,700-12,000 2,800-12,000
Total Input W 690 (390-690) 650 (160-650) 1,170 (395-1,170) 960 (160-960)
Cooling *1
Energy Efficiency SEER 17 23 17 22
Moisture Removal Pints/h 2.3 2.1 3.2 2.9
Sensible Heat Factor 0.71 0.76 0.70 0.73
Rated Capacity Btu/h 10,900 10,900 13,600 13,600
Capacity Range Btu/h 5,200-12,600 3,000-18,000 5,200-13,600 3,000-21,000
Heating at 47º F *2
Total Input W 860 (350-1,100) 750 (150-2,400) 1,160 (350-1,160) 980 (150-2,400)
HSPF (Region IV) Btu/h/W 8.2 10.55 8.2 10.55
Capacity Btu/h 7,700 12,500 8,300 13,600
Heating at 17º F *3
Total Input W 880 1,730 930 1,780
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Indoor - Outdoor S1-S2 AC 208-230V
Voltage Indoor - Outdoor S2-S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller: DC12V)
MCA A 1.0
Fan Motor F.L.A. 0.76
Airflow (Cool) DRY (CFM) 152-229-307 162-226-339 152-240-353 162-226-381
(Lo-Med-Hi) *1 WET (CFM) 134-205-275 144-202-307 134-215-318 144-202-350
Airflow (Heat) (Lo-Med-Hi) *2 DRY (CFM) 159-222-307 166-240-367 159-240-353 166-240-399
Sound Pressure Level
22-33-38 22-31-39 22-34-42 22-33-43
(Cooling) (Lo-Med-Hi) *1
dB(A)
Sound Level Pressure
Indoor Unit 22-33-38 22-31-40 22-34-42 22-33-43
(Heating) (Lo-Med-Hi) *2
External Finish Color Munsell No. 1.0Y 9.2/0.2
W: In. 30-11/16 31-7/16 30-11/16 31-7/16
Dimension Unit D: In. 8-1/4 10-1/8 8-1/4 10-1/8
H: In. 11-3/4 11-5/8 11-3/4 11-5/8
Weight Unit Lbs. 23 27 23 27
Field Drainpipe Size O.D. In. 5/8
MCA A 12
MOCP A 15
Fan Motor F.L.A. 0.52 0.56 0.52 0.56
Model (Type) DC INVERTER-driven Twin Rotary
Compressor R.L.A. 7.8 8.6 7.8 8.6
L.R.A. 9.2 10.8 9.2 10.8
Airflow CFM 1,129 1,102/1,187 1,094 1,102/1,187
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level dB(A) *1 48
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 31-1/2
Dimensions D: In. 11-1/4
H: In. 21-5/8
Weight Lbs. 75 80 82 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs., Oz. 2 2, 9 2, 5 2, 9
Oil Type (Fl. Oz.) NE022 (10.8) NE022 (29) NE022 (10.8) NE022 (29)
Gas Side O.D. 3/8
In.
Liquid Side O.D. 1/4
Refrigerant Pipe
Height Difference (Max.) 40
Ft.
Length (Max.) 65
Connection Method Indoor/Outdoor Flared/Flared
NOTES: Test conditions are based on ARI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.

14
(MSY(Z)-D30NA Model Shown)
INVERTER
MSZ heat pump (cont.)
m-Series Specifications

Indoor Unit MSZ-A15NA MSZ-A17NA MSZ-A24NA MSZ-D30NA MSZ-D36NA


Model Name
Outdoor Unit MUZ-A15NA MUZ-A17NA MUZ-A24NA MUZ-D30NA MUZ-D36NA
Rated Capacity Btu/h 15,000 16,200 22,000 30,700 33,200
Capacity Range Btu/h 3,100-15,000 3,100-16,200 4,400-22,000 9,800-30,700 9,800-33,200
Total Input W 1,690 (210-1,690) 2,070 (210-2,070) 2,880 (290-2,880) 3,850 (620-3,850) 4,360 (620-4,360)
Cooling *1
Energy Efficiency SEER 16 16 14.5
Moisture Removal Pints/h 4.7 5.1 7.3 9.9 11.3
Sensible Heat Factor 0.65 0.63 0.64 0.62
Rated Capacity Btu/h 18,000 20,100 23,200 32,600 35,200
Capacity Range Btu/h 3,400-20,900 3,600-24,400 8,700-34,000 8,700-36,000
Heating at 47º F *2
Total Input W 1,790 (250-2,330) 2,150 (250-2,330) 2,350 (260-2,570) 3,360 (520-3,600) 3,840 (520-4,100)
HSPF (Region IV) Btu/h/W 8.2 8.2 8.2
Capacity Btu/h 13,000 15,200 20,800 22,800
Heating at 17º F *3
Total Input W 1,740 1,960 2,620 3,000
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Indoor - Outdoor S1-S2 AC 208-230V
Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller: DC12V)
MCA A 1.0
Fan Motor F.L.A. 0.76
Airflow (Cool) DRY (CFM) 268-328-381 296-431-568 389-639-848
(Lo-Med-Hi) *1 WET (CFM) 240-293-342 265-385-508 350-576-763
Airflow (Heat) (Lo-Med-Hi) *2 DRY (CFM) 254-314-381 296-486-568 445-639-848
Sound Pressure Level
34-40-45 34-40-46 34-40-49 32-42-49
(Cooling) (Lo-Med-Hi) *1
dB(A)
Sound Level Pressure
Indoor Unit 34-38-44 34-40-48 34-42-49
(Heating) (Lo-Med-Hi) *2
External Finish Color Munsell No. 1.0Y 9.2/0.2
W: In. 30-11/16 30-11/16 43-5/16 46-1/16
Dimension Unit D: In. 8-1/4 8-1/4 10-1/4 11-5/8
H: In. 11-3/4 11-3/4 12-13/16 14-3/8
Weight Unit Lbs. 23 23 37 40
Field Drainpipe Size O.D. In. 5/8
MCA A 14 17 21
MOCP A 15 20 25
Fan Motor F.L.A. 0.52 0.52 0.93
Model (Type) DC INVERTER-driven Twin Rotary
Compressor R.L.A. 10.1 16
L.R.A. 12 16 20
Airflow CFM 1,249 1,729 1,941
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level dB(A) *1 50 52 55 56
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 31-1/2 33-1/16
Dimensions D: In. 11-1/4 13
H: In. 21-5/8 33-7/16 33-7/16
Weight Lbs. 88 128 141
Remote Controller Type Wireless Remote
Type R410A
Refrigerant Charge Lbs., Oz. 2, 7 4 4, 10
Oil Type (Fl. Oz.) NE022 (15.2) NEO 22(15.2) NE022 (29)
Gas Side O.D. 1/2 5/8 5/8
In.
Liquid Side O.D. 1/4 3/8
Refrigerant Pipe
Height Difference (Max.) 40 50
Ft.
Length (Max.) 65 100
Connection Method Indoor/Outdoor Flared/Flared

NOTES: Test conditions are based on ARI 210/240.


*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.

15
MXZ-Multi INVERTER heat pump
m-Series Specifications
(MSZ-A12NA Model Shown)
INVERTER

Model Name Outdoor Unit MXZ-2A20NA *5 MXZ-3A30NA *6 MXZ-4A36NA *7


Rated Capacity Btu/h 20,000 28,400 36,000
Cooling *1 Capacity Range Btu/h 7,800-20,000 12,600-28,400 12,600-36,400
Total Input W 2,150 (630-2,150) 3,250 (1,000-3,250) 3,820 (1,000-3,900) NOTES: Test conditions are based on ARI 210/240. One
indoor unit is turned off during low-speed testing under
Rated Capacity Btu/h 22,000 28,600 36,000
Indoor Unit the new test conditions. Systems actually exhibit higher
Heating at 47º F *2 Capacity Range Btu/h 8,500-22,000 11,400-36,000 11,400-43,000 energy efficiencies during normal operation.
Total Input W 1,780 (520-1,780) 2,180 (740-2,880) 3,100 (740-4,350)
Capacity Btu/h 14,500 18,800 24,600 *1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C),
Heating at 17º F *3 W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º
Total Input W 1,500 2,120 3,340
F (24º C).
Power Supply Phase,Cycle,Voltage 1 Phase, 60Hz, 208-230V *8
Indoor - Outdoor S1-S2 AC 208-230V *2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C),
Voltage
Indoor - Outdoor S2-S3 DC12-24V W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C),
MCA A 15 19 W.B. 43º F (6º C).
MOCP A 20
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C),
Fan Motor F.L.A. 0.96 0.93
W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C),
Model (Type) DC INVERTER-driven Twin Rotary W.B. 15º F (-9º C).
Compressor R.L.A. 10.1 11 14.4
L.R.A. 15 *4 Refer to pages 12 and 13 for Indoor Unit specifications.
Airflow (Cooling/Heating) *1/*2 CFM 1,485/1,640 1,365/1,605 2,068/2,068
*5 Data from combination of Indoor Units MSZ-A09NA and
Refrigerant Control Linear Expansion Valve MSZ-A12NA.
Outdoor Unit *4 Defrost Method Reverse Cycle
*6 Data from combination of Indoor Units MSZ-A09NA, MSZ-
Sound Pressure Level A09NA and MSZ-A12NA.
dB(A) 49/51 49/49 54/57
(Cooling/Heating) *1/*2
*7 Data from combination of four MSZ-A09NA Indoor Units.
External Finish Color Munsell No. 5Y 8/1 Munsell No. 3Y 7.8/1.1
*8 Indoor units receive power from outdoor units through
W: In. 33-1/16 35-7/16
field-supplied interconnected wiring.
Dimensions D: In. 13 (+1-3/16) 12-5/8 (+1-3/16)
H: In. 27-15/16 35-7/16 *9 49’ Applies to installations where the outdoor unit is
Weight Lbs. 130 148 150 installed below the indoor unit.
Remote Controller Type Wireless Remote
Power factor equals 97 percent.
Type R410A
Refrigerant Charge Lbs., Oz. 5/15 7/11 8/13 Specifications are subject to change without notice.
Oil Type (Fl. Oz.) NEO22 (23.7) NEO22 (29.4)
Gas Side O.D. A, B: 3/8 A: 1/2; B, C: 3/8 A: 1/2; B, C, D: 3/8 LIMITED WARRANTY | Six-year warranty
In. on compressor. One-year warranty on parts.
Liquid Side O.D. 1/4
(Diamond Dealers add one year to parts warranty.)
Refrigerant Pipe Height Difference (Max.) 49/33 *9
Length (Max.) Ft. 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Length (Each Indoor Unit) 82
Connection Method Indoor/Outdoor Flared/Flared

MXZ-3A30NA Combinations

Specifications are subject to change without notice.


Cooling Capacity (Btu/h) Port Adapter Requirements
Indoor Unit Power Energy Efficiency Current
Heating Capacity (Btu/h) (A)
Combinations Usage Quantity and
Size
(Unit A + Unit B + Unit C) Unit A Unit B Unit C Total (W) Port Adapter Part No.
SEER HSPF 208V 230V
MSZ-A09NA + 9,000 9,000 – 18,000 1,800 8.92 8.07
16.0 10.0 N.A.
MSZ-A09NA 10,900 10,900 – 21,800 1,700 8.43 7.62
MSZ-A09NA + 9,000 12,000 – 21,000 2,000 9.91 8.96
16.0 10.0 N.A
MSZ-A12NA 10,900 13,600 – 24,500 1,980 9.81 8.87
MSZ-A09NA + 9,000 15,000 – 24,000 2,500 12.39 11.21
16.0 10.0 N.A.
MSZ-A15NA 10,100 16,900 – 27,000 2,200 10.90 9.86
MSZ-A09NA + 9,000 16,200 – 25,200 2,700 13.38 12.10
16.0 10.0 N.A.
MSZ-A17NA 9,300 17,700 – 27,000 2,200 10.90 9.86
7,600 20,400 – 28,000 3,200 15.86 14.34 (1) PAC-SG76RJ-E
MSZ-A09NA + 3/8 X 5/8" or
16.0 10.0 or
MSZ-A24NA 7,300 19,700 – 27,000 1,980 9.81 8.87 1/2 X 5/8"
(1) MAC-A456JP-E
MSZ-A12NA + 12,000 12,000 – 24,000 2,500 12.39 11.21
16.0 10.0 N.A.
MSZ-A12NA 13,500 13,500 – 27,000 2,200 10.90 9.86
MSZ-A12NA + 11,500 14,500 – 26,000 2,800 13.88 12.55
16.0 10.0 N.A.
MSZ-A15NA 12,000 15,000 – 27,000 2,160 10.71 9.68
MSZ-A12NA + 10,800 15,200 – 26,000 2,800 13.88 12.55
16.0 10.0 N.A.
MSZ-A17NA 11,200 15,800 – 27,000 2,140 10.61 9.59
MSZ-A15NA + 13,000 13,000 – 26,000 2,800 13.88 12.55
16.0 10.0 3/8 X 1/2" (1) MAC-A454JP-E
MSZ-A15NA 13,500 13,500 – 27,000 2,120 10.51 9.50
MSZ-A15NA + 12,200 13,800 – 26,000 2,800 13.88 12.55
16.0 10.0 3/8 X 1/2" (1) MAC-A454JP-E
MSZ-A17NA 12,700 14,300 – 27,000 2,110 10.46 9.46
MSZ-A17NA + 13,000 13,000 – 26,000 2,800 13.88 12.55
16.0 10.0 3/8 X 1/2" (1) MAC-A454JP-E
MSZ-A17NA 13,500 13,500 – 27,000 2,100 10.41 9.41
MSZ-A09NA + MSZ-A09NA 9,000 9,000 9,000 27,000 2,860 14.18 12.82
16.0 10.0 1/2 X 3/8" (1) MAC-A455JP-E
+ MSZ-A09NA 9,500 9,500 9,500 28,500 2,180 10.80 9.77
MSZ-A09NA + MSZ-A09NA 8,500 8,500 11,400 28,400 3,250 16.11 14.57
16.0 10.0 1/2 X 3/8" (1) MAC-A455JP-E
+ MSZ-A12NA 8,600 8,600 11,400 28,600 2,180 10.80 9.77
MSZ-A09NA + MSZ-A09NA 7,750 7,750 12,900 28,400 3,250 16.11 14.57
16.0 10.0 N.A.
+ MSZ-A15NA 7,800 7,800 13,000 28,600 2,180 10.80 9.77
MSZ-A09NA + MSZ-A09NA 7,300 7,300 13,800 28,400 3,250 16.11 14.57
16.0 10.0 N.A.
+ MSZ-A17NA 7,350 7,350 13,900 28,600 2,180 10.80 9.77

16
MXZ-2A20 NA (2:1) MXZ-3A30 NA ( 3 : 1 , 2 : 1 )
Outdoor Unit Outdoor Uni t

M SZ-A12N A

MXZ-2A20NA Combinations MSZ-A09NA


M SZ-A09N A Indo o r U ni ts

Specifications are subject to change without notice.


Indo o r U ni ts
Indoor Unit Cooling Capacity (Btu/h) Power Energy Current
M S Z- A 12N A
(Unit A + Unit B) Heating Capacity (Btu/h) Usage Efficiency (A) (Two indoor units must be installed.)
(At least two indoor units must be installed.)
Combinations Unit A Unit B Total (W) SEER HSPF 208V 230V
MSZ-A09NA + 9,000 9,000 18,000 1,740 8.62 7.8
16.0 8.5 - Refer to combination chart for port adaptor references -
MSZ-A09NA 10,900 10,900 21,800 1,820 9.02 8.16
MSZ-A09NA + 8,500 11,500 20,000 2,150 10.66 9.64
16.0 8.5 MX Z-4A36NA (4:1, 3:1) Outdoor Unit
MSZ-A12NA 9,500 12,500 22,000 1,780 8.82 7.98
MSZ-A09NA + 7,500 12,500 20,000 2,150 10.66 9.64
16.0 8.5
MSZ-A15NA* 8,250 13,750 22,000 1,780 8.82 7.98 M SZ - A 09N A
Indo or U ni ts
MSZ-A12NA + 10,000 10,000 20,000 2,150 10.66 9.64
16.0 8.5
MSZ-A12NA 11,000 11,000 22,000 1,780 8.82 7.98
*Port Adapter size = 3/8" x 1/2", Qty = 1, Part No. = MAC-A454JP-E
M SZ - A 12N A
Indo or U ni ts

(At least three indoor units must be installed.)


MXZ-4A36NA Combinations

Specifications are subject to change without notice.


Energy Current (A) Port Adapter
Indoor Unit Cooling Capacity (Btu/h)
Efficiency Requirements
Power
Combinations
Heating Capacity (Btu/h) Usage Quantity and
(Unit A + Unit B +
(W) SEER HSPF 208V 230V Size Port Adapter
Unit C + Unit D)
Unit A Unit B Unit C Unit D Total Part No.
MSZ-A09NA + MSZ-A09NA 9,000 9,000 9,000 – 27,000 2,860 14.18 12.82
16.0 8.5 N.A.
+ MSZ-A09NA 10,800 10,800 10,800 – 32,400 2,700 13.38 12.10
MSZ-A09NA + MSZ-A09NA 9,000 9,000 12,000 – 30,000 3,270 16.21 14.66
16.0 8.5 N.A.
+ MSZ-A12NA 10,000 10,000 12,400 – 32,400 2,700 13.38 12.10
MSZ-A09NA + MSZ-A09NA 8,800 8,800 14,500 – 32,100 3,500 17.35 15.69
16.0 8.5 N.A.
+ MSZ-A15NA 8,900 8,900 14,600 – 32,400 2,700 13.38 12.10
MSZ-A09NA + MSZ-A09NA 8,200 8,200 15,700 – 32,100 3,500 17.35 15.69
16.0 8.5 N.A.
+ MSZ-A17NA 8,400 8,400 15,600 – 32,400 2,700 13.38 12.10
6,900 6,900 18,300 – 32,100 3,500 17.35 15.69 3/8 X 5/8” (1) PAC-SG76RJ-E
MSZ-A09NA + MSZ-A09NA
16.0 8.5 or or
+ MSZ-A24NA 7,800 7,800 16,800 – 32,400 2,700 13.38 12.10 1/2 X 5/8” (1) MAC-A456JP-E
MSZ-A09NA + MSZ-A12NA 8,700 11,700 11,700 – 32,100 3,500 17.35 15.69
16.0 8.5 N.A.
+ MSZ-A12NA 9,400 11,500 11,500 – 32,400 2,700 13.38 12.10
MSZ-A09NA + MSZ-A12NA 8,000 10,700 13,400 – 32,100 3,500 17.35 15.69
16.0 8.5 N.A.
+ MSZ-A15NA 8,300 10,400 13,700 – 32,400 2,700 13.38 12.10
MSZ-A09NA + MSZ-A12NA 7,600 10,100 14,400 – 32,100 3,500 17.35 15.69
16.0 8.5 N.A.
+ MSZ-A17NA 7,900 9,900 14,600 – 32,400 2,700 13.38 12.10
MSZ-A09NA + MSZ-A15NA 7,500 12,300 12,300 – 32,100 3,500 17.35 15.69
16.0 8.5 3/8 X 1/2” (1) MAC-A454JP-E
+ MSZ-A15NA 7,600 12,400 12,400 – 32,400 2,700 13.38 12.10
MSZ-A09NA + MSZ-A15NA 7,100 11,700 13,300 – 32,100 3,500 17.35 15.69
16.0 8.5 3/8 X 1/2” (1) MAC-A454JP-E
+ MSZ-A17NA 7,200 11,900 13,300 – 32,400 2,700 13.38 12.10
MSZ-A09NA + MSZ-A17NA 6,700 12,700 12,700 – 32,100 3,500 17.35 15.69
16.0 8.5 3/8 X 1/2” (1) MAC-A454JP-E
+ MSZ-A17NA 7,000 12,700 12,700 – 32,400 2,700 13.38 12.10
MSZ-A12NA + MSZ-A12NA 10,700 10,700 10,700 – 32,100 3,500 17.35 15.69
16.0 8.5 N.A.
+ MSZ-A12NA 10,800 10,800 10,800 – 32,400 2,700 13.38 12.10

MSZ-A12NA + MSZ-A12NA 9,900 9,900 12,300 – 32,100 3,500 17.35 15.69


16.0 8.5 N.A.
+ MSZ-A15NA 9,700 9,700 13,000 – 32,400 2,700 13.38 12.10

MSZ-A12NA + MSZ-A12NA 9,400 9,400 13,300 – 32,100 3,500 17.35 15.69


16.0 8.5 N.A.
+ MSZ-A17NA 9,300 9,300 13,800 – 32,400 2,700 13.38 12.10

MSZ-A12NA + MSZ-A15NA 9,100 11,500 11,500 – 32,100 3,500 17.35 15.69


16.0 8.5 3/8 X 1/2” (1) MAC-A454JP-E
+ MSZ-A15NA 9,000 11,700 11,700 – 32,400 2,700 13.38 12.10

MSZ-A09NA + MSZ-A09NA 9,000 9,000 9,000 9,000 36,000 3,820 18.55 16.78
16.0 8.5 1/2 X 3/8” (1) MAC-A455JP-E
+ MSZ-A09NA + MSZ-A09NA 9,000 9,000 9,000 9,000 36,000 3,100 15.05 13.61

MSZ-A09NA + MSZ-A09NA 8,300 8,300 8,300 11,100 36,000 3,820 18.55 16.78
16.0 8.5 1/2 X 3/8” (1) MAC-A455JP-E
+ MSZ-A09NA + MSZ-A12NA 8,300 8,300 8,300 11,100 36,000 3,100 15.05 13.61

MSZ-A09NA + MSZ-A09NA 7,700 7,700 7,700 12,900 36,000 3,820 18.55 16.78
16.0 8.5 N.A.
+ MSZ-A09NA + MSZ-A15NA 7,700 7,700 7,700 12,900 36,000 3,100 15.05 13.61

MSZ-A09NA + MSZ-A09NA 7,700 7,700 10,300 10,300 36,000 3,820 18.55 16.78
16.0 8.5 1/2 X 3/8” (1) MAC-A455JP-E
+ MSZ-A12NA + MSZ-A12NA 7,700 7,700 10,300 10,300 36,000 3,100 15.05 13.61

*Port Adapter size = 3/8" x 1/2", Qty = 1, Part No. = MAC-A454JP-E

17
P-Series
Commercial, institutional
AND large residential

The Mr. Slim P-Series delivers flexible and


convenient cooling and heating solutions to
almost any commercial, institutional or large
residential application. Choose from small,
quiet indoor and outdoor units that oper-
ate with the increased efficiency you need.
Whether in a church, office building, school,
nursing home, restaurant, retail store, or
equipment room, the compact design of
the P-Series indoor units makes cooling
and heating difficult spaces a breeze. With
wall-mounted, ceiling-recessed and ceiling-
suspended options, the P-Series is the
does not even have to be in the space
shared with the indoor unit. Features
Hot-start System
perfect solution for almost any building. of the controller include a weekly timer, Mr. Slim heat pumps use our hot-start
The P-Series provides up to 42,000 Btu/h temperature range limiting, auto-off, technology to provide warmth from the
of cooling or heating performance. expanded fault codes, and service beginning by ramping up fan speed as
call number display. the coil warms. When you want warm
Inverter Technology air without annoying drafts, that’s what

Inverter-driven
Low Ambient Operation you’ll get.

compressor INVERTER
technology
gives Mr. Slim systems a
The ability of these units to operate
effectively in low temperatures along
Installation Service
higher degree of cooling and heating abilities with the addition of a low-ambient wind and Maintenance Ease
that outperform and manage energy more baffle accessoryallows for a space to be
efficiently than conventional systems. P-Series outdoor units are designed
air-conditioned even when it is as low
Desired room temperature is reached more with easy service and maintenance
as 0˚ F outside. This cooling ability is
quickly and maintained more consistently. in mind. Maintenance points are
important when dealing with electronic
This capability eliminates the peaks and located behind easy-access panels
equipment rooms, telecom substations,
valleys of temperature swings that we’re to make installation and service
surveillance mechanical rooms, restaurant
used to with conventional units. effortless for a trained technician. Four-
kitchens, fitness centers and more.
way piping access allows connection in
The PKA and PLA indoor units can be used four directions: front, rear, right and
with our Hyper-Heating INVERTER (H2i™) Redi-charged Systems bottom (all PUY/PUZ models). Using only
outdoor heat pump units. These innovative three polarity sensitive wires plus a ground
H2i outdoor units are designed to deliver P-Series outdoor units come with conductor run from the outdoor to the
consistent, efficient cooling and heating enough refrigerant to be installed indoor unit, providing both power and
even in extreme low outdoor temperatures 70 feet (PUY(Z)12-36) and up to 100 communication connections. Two non-
from a single INVERTER-driven feet (PUY(Z)42) from the indoor units. polar wires connect the indoor unit and
compressor system. Linesets can be run up to 100 feet from wall-mounted controller. This wiring design
PUY(Z)12-18 outdoor units and 165 feet helps avoid installation errors. An optional
from PUY(Z)24-42 outdoor units when
Flexible Control additional charge is added. Thanks to
wireless remote controller kit is available
for the P-Series ceiling-mounted
unique design profiles and R410A refriger- indoor units.
Convenient and efficient zone control means
ant, these systems are easier to fit into any
you can cool or heat only the spaces in use.
space. R410A is environmentally friendly
You can even have single or dual control-
with zero Ozone Depletion Potential (ODP).
lers connected to one system. The controller

P K A W a ll- mounte d PL A C e i l i n g -r e c e s s e d PC A C e i l i n g -s u s p e nded


Air Conditioners and Air Conditioners and A i r C o n d i t i o n e r s and
P -Series Wired He a t P ump s H e a t Pu m p s H e a t Pu m p s
Re m ote Con troller 12, 000 to 34, 200 B tu/ h 1 2 , 0 0 0 t o 4 2 , 0 0 0 Bt u / h 2 4 , 0 0 0 t o 4 2 , 0 0 0 Bt u / h
[p gs. 24- 26] [ p g s . 2 7 -2 9 ] [ pg s . 3 0 -3 2 ]

18
Features Benefits
INVERTER You can enjoy high-speed cooling and heating
Technology and consistent delivery of comfort year-round.

Quiet operation
You can hold a board meeting or teach a class
in quiet comfort.

There’s no need to shut down for major


No Ductwork construction because installation is quick
and easy.
 ou can cool and heat only those spaces
Y
zone control desired for maximum control and
energy efficiency.
advanced Built-in electronics ensure efficient operation and
microprocessor maximum performance for optimum comfort.
controls
low ambient This feature is perfect for computer network
cooling down centers and telecom equipment rooms that
to 0˚ F outdoors need help to stay cool down to 0˚ Foutside
(requires wind baffle)

environmentally Mr. Slim systems use R410A, an


friendly environmentally-friendly refrigerant.

SET TEMPERATURE

TIMER MENU
ON/OFF
More Compact Inverter-driven Outdoor Units
FAN SPEED

MODE
FILTER These Mr. Slim units employ advanced Pulse Amplitude Modulation
TEST RUN
(PAM). PAM adjusts the form of the current wave to emulate the
SET TIME
CHECK
form of the supply voltage wave so that 98 percent of input
power is effectively utilized.
AIRFLOW UP/DOWN
PUZ-HA
TIMER ON/OFF
LOUVER PUY/PUZ

VENTILATION

(MULTILINGUAL)

12,000-18,000 24,000-36,000 42,000 36,000


Btu/h Btu/h Btu/h Btu/h

19
H2i
TM

HYPER-HEATING INVERTER The Next Generation in


P-Series HEAT PUMP SYSTEM Heat Pump Technology
34,200 to 36,000 Btu/h Capacity These H2i outdoor units give a new level of performance
to Mr. Slim P-Series models, providing the extra heat-
generating power it takes to deliver comfort and consistency
Unequaled Year-round Comfort in extreme climates. H2i units use Mitsubishi Electric’s
The cooling and heating success of Mitsubishi Electric’s INVERTER-driven scroll compressor technology to achieve
INVERTER heat pump systems is well-documented. Our the desired room temperature quickly and maintain it
Hyper-Heating INVERTER (H2i) technology advances the consistently while simultaneously conserving energy. Plus
process a step further with the added benefit of year- with the integration of our exclusive H2i flash technology,
round comfort with a single system even on the coldest these units recover heat energy that is normally wasted in
days of the year in most places. The 3-ton wall-mounted the flash process at the outdoor coil. This process helps
or ceiling-recessed indoor units connected to the H2i the H2i system overcome issues commonly associated with
outdoor units are flexible enough to satisfy almost any conventional heat pumps such as decreases in low-side
light commercial or institutional renovation or new pressure, refrigerant mass flow rate and operational capacity.
construction project. As a result H2i units exhibit 100 percent of rated heating
capacity at 5˚ F and 80 percent at -13˚ F outdoor ambient
temperatures (see Figure 1). Plus they use R410A
environmentally-friendly refrigerant.

H2i heat pumps offer a variety of features designed to


take the worry out of temperature control such as automatic
restart in the case of power outages and automatic cool/heat
changeover. And its long line-length capabilities of up to
245 ft. expand application possibilities.

20
(Figure 1)

Sometimes cooling spaces such as computer or mechanical


rooms and kitchens is necessary even when the temperature
is below freezing. Air conditioning down to 0˚ F outdoor
ambient temperature is possible with the addition of a wind
baffle. Whether cooling or heating the H2i P-Series gives you Indoor Units:
the flexibility to temper extreme outdoor temperatures.

PKA
Warm Air Quickly! The PKA indoor unit is a compact
At startup a special circuit quickly delivers refrigerant to and quiet wall-mounted unit that delivers exceptional
the air-conditioning cycle. This process rapidly increases cooling and heating performance.
the mass flow rate in the system. As a result air at • Hard-wired, wall-mounted, remote controller
comfortable temperatures begins flowing from indoor (-FA model) or wireless (-FAL model)
units right away. Even at an outdoor temperature of -13˚ F, • Adjustable vane control
the H2i system can discharge 100˚ F temperature air from • Easy-clean filters
the indoor units. At 5˚ F outdoor temperature and above, the
discharge temperature reaches an impressive 110˚ F with a PLA
40˚ F temperature rise (see Figure 2). This feature translates PLA-A**-BA ceiling-recessed
into a comfortable climate in all zones of a home or office, indoor unit offers increased application flexibility
and ease of installation especially in tight spaces.
whether cooling or heating, no matter the
• Independent vane motor control: five fixed settings
temperature outside.
plus swing
• Auto wave airflow in heating mode: unit independently
cycles through all vertical positions for a more even
heat distribution
• Built-in drain lift mechanism for condensate removal; lifts
up to 33-7/16 in.
• Ventilation air intake
• Easy-clean filters
• Optional i-see™ sensor accessory

(Figure 2)

21
Two in One
If you have a large space such as a long room
or hallway which would be considered one
zone, two indoor units can be connected to
the outdoor unit to cool or heat the space and
provide the maximum amount of comfort. The
process in which two indoor units act as one to
spread the outdoor unit’s capacity over a large
area is called Twinning.

Indoor Room

Outdoor Unit

Heating Performance
at Low Temperatures
Our Hyper-Heating INVERTER system provides
outstanding heating performance at extremely
low temperatures while keeping effective energy
usage at the forefront. Take a look at these
impressive COP (Coefficient of Performance)
values. The Mr. Slim H2i P-Series systems are
able to maximize efficiency at low temperatures
while providing tremendous heating output.

H2i
COP PKA PLA
47˚ F 3.59 3.45
17˚ F 2.10 2.10
5˚ F 1.90 1.90

22
INVERTER
H2i Heat pump
TM

P-Series Specifications

FA = Wired Controller; FAL = Wireless Controller

Specifications are subject to change without notice.


Indoor Unit PKA-A36FA(L) PLA-A36BA

FA = Wired Controller; FAL = Wireless Controller


Model Name
Outdoor Unit PUZ-HA36NHA PUZ-HA36NHA
Rated Capacity Btu/h 34,200 36,000
Capacity Range Btu/h 18,000-34,200 18,000-36,000
Total Input W 2,950 3,120
Cooling *1
Energy Efficiency SEER 16.0
Moisture Removal Pints/h 7.1 6.8
Sensible Heat Factor 0.77 0.79
Rated Capacity Btu/h 38,000
Capacity Range Btu/h 18,000-40,000
Heating at 47° F *2
Total Input W 3,100 3,230
HSPF Region (IV) Btu/h/W 9.4
Capacity Btu/h 38,000
Heating at 17° F *3
Total Input W 5,300
Capacity Btu/h 38,000
Heating at 5° F *4
Total Input W 5,860
Power Supply Phase, Cycle, Voltage 1-Phase, 60Hz, 208/230V *5
Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC24V
Indoor - Remote Controller DC12V: For Wired Controller (FA) DC12V
MCA A 1.0 2.0
Fan Motor F.L.A. 0.52 1.00
Fan Motor Output W 70 120
DRY (CFM) 780-990 (Lo-Hi) 710-810-920-1,060 (Lo-M1-M2-Hi)
Airflow
WET (CFM) 700-890 (Lo-Hi) 670-770-880-1,030 (Lo-M1-M2-Hi)
Sound Pressure Level dB(A) 46-49 (Lo-Hi) 32-34-37-40 (Lo-M1-M2-Hi)
Indoor Unit External Finish Color Munsell No. 3.4Y 7.7/0.8 Grille: 6.4Y 8.9/0.4
W: In. 66-1/8 33-1/16 (Grille: 37-3/8)
Dimension Unit D: In. 9-1/4 33-1/16 (Grille: 37-3/8)
H: In. 13-3/8 11-3/4 (Grille: 1-3/8)
Weight Unit Lbs. 62 55 (Grille: 13)
Drain Lift Mechanism (Included) H: In. N/A 33-7/16
Field Drainpipe Size In. I.D.: 13/16 O.D.: 1-1/4
MCA A 28
MOCP A 40
Fan Motor F.L.A. 0.4 + 0.4
Fan Motor Output W 60 + 60
Model DC INVERTER-driven Scroll
Compressor R.L.A. 18
L.R.A. 27.5
Airflow CFM 3,530
Outdoor Unit Refrigerant Control Electronic Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level (Cooling) *1 dB(A) 52
Sound Pressure Level (Heating) *2 dB(A) 53
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 37-3/8
Dimensions D: In. 13 + 1-3/16
H: In. 53-1/8
Weight Lbs. 267
Remote Controller Located with Indoor Unit Located with Grille
Type R410A
Refrigerant Charge Lbs. 12
Oil Type (fl. oz.) FV50S (45)
Gas Side O.D. In. 5/8
Refrigerant Pipe
Liquid Side O.D. In. 3/8
Height Difference (Max.) Ft. 100
Refrigerant Pipe Length
Length (Max.) Ft. 245
Connection Method Flared
Cooling 23° F D.B. to 115° F D.B. (or 0° F D.B. to 115° F D.B. with Wind Baffle Accessory Installed)
Operating Temperature Range
Heating -13° F W.B. to +59° F W.B.

NOTES:
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19.4º C); *3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); *5 Indoor units receive power
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C). Outdoor: D.B. 17º F (-8º C ), W.B. 15º F (-9º C ). from outdoor units through
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); *4 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); field-supplied interconnected
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C). Outdoor: D.B. 5º F (-15º C), W.B. 5º F (-15º C). wiring.
LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.

23
pkA
(GA/GAL,fA/FAl)
Wall-mounted series
12,000 to 34,200 Btu/h
Capacity

P K A Ind oor Unit


(The same indoor unit is used for both
cooling and heat pump systems.)

The PKA-Series fills small, critical and


larger spaces with substantial cooling and
PK A-L S er i es
heating from a compact, wall-mounted PAR-2 1 MAA W i r e d C o n t r o l l e r W i r e l ess C o n t r o l l er
package. Walk into any room where a PKA These Mr. Slim systems come with either a wired
system is installed, and all you’ll notice is the (GA/FA) or wireless (GAL/FAL) remote controller
perfectly comfortable climate. What you may that puts you in command of your personal comfort.

not notice is the unit itself, which mounts high


on the wall and blends into most spaces. The
PKA-Series features an Auto Changeover Lightweight, Easy-to-
mode that automatically switches back
and forth between cooling and heating
install Indoor Unit
operation to compensate for indoor The smallest PKA unit measures about 39”
and outdoor temperature fluctuations. wide, 13” tall and 9” deep. It weighs just
35 lbs. and is easily installed above windows
Auto Vane Control or doorways and can typically be installed by
just two licensed installers in about a half day.
With a simple press of the OFF button And Mr. Slim PKA-Series models don’t even
the vane closes to cover the air outlet for require ductwork, only a small three-inch
a clean presentation when not in use. During opening in the wall or ceiling, so they can
operation the vane can be adjusted with the be installed in some of the toughest spaces,
remote controller to the perfect position to even on brick and masonry walls.
direct the airflow horizontally in cooling mode
or towards the floor in heating mode, keeping
room temperature even and comfortable.
Ultimate Comfort Meets
Ultimate Convenience
Easy-clean Filters Select from a wall-mounted, hard-wired con-
Convenient tabs let you remove the troller (GA/FA) or a wireless remote controller
washable filters quickly and easily for faster (GAL/FAL) for ultimate comfort control. The
cleaning. You’ll also save time and money hand-held Mr. Slim LCD wireless remote con-
because you won’t need to replace the filters. troller is easier to use than most TV remotes.
The set-temperature display is large and
easy to read. Using the 24-hour timer, you
can get the unit operation to start and stop at
specified times and to repeat daily. And the
convenient remote provides easy control of
the Fan Speed as well as the cool, heat,
AUTO and Dry modes from anywhere
in the room.

24
(PKA-A30FA Model Shown)
INVERTER
PKA COOLING-ONLY
P-Series Specifications
GA/FA = Wired controller
GAL/FAL = Wireless controller
BS = Seacoast Protection
PKA-A12GA PKA-A18GA PKA-A24FA PKA-A30FA PKA-A36FA
Indoor Unit
PKA-A12GAL PKA-A18GAL PKA-A24FAL PKA-A30FAL PKA-A36FAL
Model Name
PUY-A12NHA PUY-A18NHA PUY-A24NHA PUY-A30NHA PUY-A36NHA
Outdoor Unit
PUY-A12NHA-BS PUY-A18NHA-BS PUY-A24NHA-BS PUY-A30NHA-BS PUY-A36NHA-BS
Rated Capacity Btu/h 12,000 18,000 24,000 30,000 34,200
Capacity Range Btu/h 6,000-12,000 8,000-18,000 12,000-24,000 12,000-30,000 12,000-34,200
Total Input W 1,210 2,240 2,650 4,400 5,030
Cooling *1
Energy Efficiency SEER 13.8 14.1 13.5 13.0 13.1
Moisture Removal Pints/h 1.5 4.8 4.7 8.1 7.1
Sensible Heat Factor 0.86 0.70 0.78 0.70 0.77
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Indoor - Outdoor S1-S2 AC 208-230V
Indoor - Outdoor S2-S3 DC24V
Voltage
Indoor - Remote Controller DC12V : Wired Type (GA/FA)
Indoor - Remote Controller Wireless Type (GAL/FAL)
MCA A 1
Fan Motor F.L.A. 0.33 0.43 0.52
Fan Motor Output W 30 45 70
Airflow (Lo-M1-M2-Hi) or DRY (CFM) 320-350-390-425 530-705 780-990
(Lo-Hi) WET (CFM) 290-315-350-380 480-635 700-890
Sound Pressure Level
dB(A) 36-38-41-43 39-45 46-49
(Lo-M1-M2-Hi) or (Lo-Hi)
Indoor Unit
External Finish Color Munsell No. 0.70Y 8.59/0.97 Munsell No. 3.4Y 7.7/0.8
W: In. 39 55-1/8 66-1/8
Dimension Unit D: In. 9-1/4
H: In. 13-3/8
Weight Unit Lbs. 35 53 62
Field Drainpipe Size I.D. In. 13/16
MCA A 13 18 25
MOCP A 15 20 30 40
Fan Motor F.L.A. 0.35 0.75
Fan Motor Output W 40 75
Model (Type) DC INVERTER-driven Twin Rotary
Compressor R.L.A 12
L.R.A. 14 17.5
Airflow CFM 1,200 1,940
Outdoor Unit Refrigerant Control Linear Expansion Valve
Sound Pressure Level
dB(A) 46 48
(Cooling) *1
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 31-1/2 37-3/8
Dimensions D: In. 13 + 7/8 13 + 1-3/16
H: In. 23-5/8 37-1/8
Weight Lbs. 90 97 163
Remote Controller Type GA/FA = Wired; GAL/FAL = Wireless (Located with Indoor Unit)
Type R410A
Refrigerant Charge Lbs., Oz. 2, 14 3, 12 6
Oil Type (Fl. Oz.) MEL56 (20) MEL56 (28)
Gas Side O.D. 1/2 5/8
In.
Liquid Side O.D. 1/4 3/8
Refrigerant Pipe
Height Difference (Max.) 100
Ft.
Length (Max.) 100 165
Connection Method Indoor/Outdoor Flared/Flared

NOTES: Test conditions are based on ARI 210/240.


*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.

LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.

25
(PKA-A30FA Model Shown)
INVERTER
PKA HEAT PUMP
P-Series Specifications
GA/FA = Wired controller
GAL/FAL = Wireless controller
BS = Seacoast Protection
PKA-A18GA PKA-A24FA PKA-A30FA PKA-A36FA
Indoor Unit
PKA-A18GAL PKA-A24FAL PKA-A30FAL PKA-A36FAL
Model Name
PUZ-A18NHA PUZ-A24NHA PUZ-A30NHA PUZ-A36NHA
Outdoor Unit
PUZ-A18NHA-BS PUZ-A24NHA-BS PUZ-A30NHA-BS PUZ-A36NHA-BS
Rated Capacity Btu/h 18,000 24,000 30,000 34,200
Capacity Range Btu/h 8,000-18,000 12,000-24,000 12,000-30,000 12,000-34,200
Cooling *1 Total Input W 2,240 2,650 4,400 5,030
Energy Efficiency SEER 14.1 13.5 13 13.1
Moisture Removal Pints/h 4.8 4.7 8.1 7.1
Sensible Heat Factor 0.70 0.78 0.70 0.77
Rated Capacity Btu/h 19,000 26,000 32,000 37,000
Capacity Range Btu/h 8,000-20,000 12,000-28,000 12,000-34,000 12,000-38,000
Heating at 47º F *2
Total Input W 2,130 2,570 3,660 3,610
HSPF (Region IV) Btu/h/W 8.3 8.5 8.3
Capacity Btu/h 13,000 16,000 23,000 25,000
Heating at 17º F *3
Total Input W 1,670 2,200 3,050 3,070
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208-230V *4
Indoor - Outdoor S1-S2 AC 208/230V
Indoor - Outdoor S2-S3 DC24V
Voltage
Indoor - Remote Controller DC12V : Wired Type (GA/FA)
Indoor - Remote Controller Wireless Type (GAL/FAL)
MCA A 1
Fan Motor F.L.A. 0.33 0.43 0.52
Fan Motor Output W 30 45 70
Airflow (Lo-M1-M2-Hi) or DRY (CFM) 320-350-390-425 530-705 780-990
(Lo-Hi) WET (CFM) 290-315-350-380 480-635 700-890
Sound Pressure Level
dB(A) 36-38-41-43 39-45 46-49
Indoor Unit (Lo-M1-M2-Hi) or (Lo-Hi)
External Finish Color Munsell No. 0.70Y 8.59/0.97 Munsell No. 3.4Y 7.7/0.8
W: In. 39 55-1/8 66-1/8
Dimension Unit D: In. 9-1/4
H: In. 13-3/8
Weight Unit Lbs. 35 53 62
Field Drainpipe Size I.D. In. 13/16
MCA A 13 18 25
MOCP A 20 30 40
Fan Motor F.L.A. 0.35 0.75
Fan Motor Output W 40 75
Model (Type) DC INVERTER-driven Twin Rotary
Compressor R.L.A. 12
L.R.A. 14 17.5
Airflow CFM 1,200 1,940
Refrigerant Control Linear Expansion Valve
Outdoor Unit Defrost Method Reverse Cycle
Sound Pressure Level 46 48
(Cooling) *1
dB(A)
Sound Pressure Level
47 50
(Heating) *2
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 31-1/2 37-3/8
Dimensions D: In. 13 + 7/8 13 + 1-3/16
H: In. 23-5/8 37-1/8
Weight Lbs. 99 165
Remote Controller Type GA/FA: Wired Controller; GAL/FAL: Wireless Controller (Located with Indoor Unit)
Type R410A
Refrigerant Charge Lbs., Oz. 3, 12 6
Oil Type (Fl. Oz.) MEL56 (20) MEL56 (28)
Gas Side O.D. 1/2 5/8
Refrigerant Pipe In.
Liquid Side O.D. 1/4 3/8
Height Difference (Max.) Ft. 100
Refrigerant Pipe Length
Length (Max.) 100 165
Connection Method Indoor/Outdoor Flared/Flared
NOTES: Test conditions are based on ARI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8.3º C), W.B. 15º F (-9º C).
*4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.

26
ceiling-recessed series
PLA PL A I n d o o r U n i t
(Same indoor unit is used for both
cooling and heat pump systems)
12,000 to 42,000
Btu/h Capacity
If there’s at least a foot of space above
your ceiling, the PLA-Series is for you.
These models combine powerful cooling
and heating in an elegant cassette design Auto Fan Speed Feature
that recesses into the ceiling. When
Choose from four set fan speeds or auto
installed, the attractive, low-profile grille is
fan speed to ensure faster achievement of
all you see. With its ventilation air intake
room temperature. Auto fan speed mode
capability and four-way discharge airflow,
allows the fan to adjust its speed based
the PLA-Series gives you plenty of com-
on the degree of differential between
fortable airflow options. These units even
set-point and room temperature.
contain branch duct knockouts for either Auto Fan Speed Mode

a round or a rectangular duct, allowing Low Mid1 Mid2 High Auto


for the air conditioning of a smaller
adjacent space.

Auto Wave Feature


Auto Cooling/Heating
(HEATING mode)
Changeover
In the HEATING mode each air outlet
Heat pump systems will automatically vane operates independently, distributing
switch back and forth between cooling warm air in multiple directions for the
and heating to compensate for tempera- best in room heating.
ture fluctuations in a room.

Wider Air Stream


Longer air outlets deliver wider air
streams for improved air distribution i-see™ Sensor Accessory
and energy savings. This feature means
In addition to the return air temperature,
quieter air delivery with fewer drafts and
the PLA-A**BA four-way ceiling cassette
great overall cooling and
with the field-installed i-see sensor
heating coverage. Unit Features:
measures the floor temperature in real
time, observing the room vertically
Previous Model PLA-A**ABA • Built-in drain lift mechanism for
for better management of sensible
condensate removal; lifts up to
temperature (temperature felt by the 33-7/16 inches with built-in
Air outlet: 16 - 3/16 In. Air outlet: 19 - 11/16 In. occupant). The i-see sensor measures fail-safe sensor
the infrared rays generated from the • Easy to install with access
surrounding wall and floor surface at an to suspension rods through
angle of 360°. The infrared ray energy is corner pockets
converted into a temperature value. The • Ventilation air intake

Independent Vane i-see sensor rotates 90° slowly in five-


second intervals for correct measurement
• Easy to maintain, long-life filter,
which is washable and provides
Motor Control of temperature to cover the full floor about 2,500 hours of use before
cleaning is needed, depending
space. When combined with the auto fan on use
Each of the four vanes can be set by speed mode, air can be directed to the
the wired remote controller to operate farthest corners of the room for enhanced i-see sensor detail
independently to match the room layout. temperature
Specific vane settings include five fixed coverage.
directions plus swing.

27
INVERTER
PLA COOLING-ONLY
(PLA-A36BA Model Shown P-Series Specifications
with optional I-SEE™ sensor)

BS = Seacoast Protection
Indoor Unit PLA-A12BA PLA-A18BA PLA-A24BA PLA-A30BA PLA-A36BA PLA-A42BA
Model Name PUY-A12NHA PUY-A18NHA PUY-A24NHA PUY-A30NHA PUY-A36NHA PUY-A42NHA
Outdoor Unit
PUY-A12NHA-BS PUY-A18NHA-BS PUY-A24NHA-BS PUY-A30NHA-BS PUY-A36NHA-BS PUY-A42NHA-BS
Rated Capacity Btu/h 12,000 18,000 24,000 30,000 35,000 42,000
Capacity Range Btu/h 6,000-12,000 8,000-18,000 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000
Total Input W 1,260 1,940 2,500 4,100 4,500 4,600
Cooling *1
Energy Efficiency SEER 13.5 14.2 13.6 14.2 14.4
Moisture Removal Pints/h 1.7 3.0 5.1 7.2 8.1 10.9
Sensible Heat Factor 0.84 0.81 0.76 0.73 0.74 0.71
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208-230V *2
Indoor - Outdoor S1-S2 AC 208/230V
Voltage Indoor - Outdoor S2-S3 DC24V
Indoor - Remote Controller DC12V : Wired Type
MCA A 1 2
Fan Motor F.L.A. 0.51 1.00
Fan Motor Output W 50 120
DRY (CFM) 390-420-460-530 420-490-570-640 490-570-640-740 710-810-920-1,060 780-880-990-1,090
Airflow (Lo-M1-M2-Hi)
WET (CFM) 350-390-420-490 390-460-530-600 460-530-600-710 670-770-880-1,030 740-850-950-1,060
External Pressure Pa 0
Sound Pressure Level
dB(A) 27-28-29-31 28-29-31-32 28-30-32-34 32-34-37-40 34-36-39-41
Indoor Unit (Lo-M1-M2-Hi)
External Finish Color (Panel) Munsell No. 6.4Y 8.9/0.4
W: In. 33-1/16 (37-3/8)
Dimension Unit (Panel) D: In. 33-1/16 (37-3/8)
H: In. 10-3/16 (1-3/8) 11-3/4 (1-3/8)
Weight Unit (Panel) Lbs. 49 (13) 51 (13) 55 (13)
Drain Lift Mechanism
H: In. 33-7/16
(included)
Field Drainpipe Size O.D. In. 1-1/4
MCA A 13 18 25 26
MOCP A 15 20 30 40
Fan Motor F.L.A. 0.35 0.75 0.4 + 0.4
Fan Motor Output W 40 75 86 + 86
Model INVERTER-driven
DC INVERTER-driven Twin Rotary
(Type) Scroll
Compressor
R.L.A. 12 20
L.R.A. 14 17.5 27.5
Outdoor Unit Airflow CFM 1,200 1,940 3,530
Refrigerant Control Linear Expansion Valve
Sound Pressure Level
dB(A) 46 48 51
(Cooling) *1
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 31-1/2 37-3/8
Dimensions D: In. 13 + 7/8 13 + 1-3/16
H: In. 23-5/8 37-1/8 53-1/8
Weight Lbs. 90 97 163 258
Remote Controller Type Wired Remote Controller Packaged with Grille
Type R410A
Refrigerant Charge Lbs., Oz. 2, 14 3, 12 6 10
Oil Type (Fl. Oz.) MEL56 (20) MEL56 (28) FV50S (45)
Gas Side O.D. 1/2 5/8
In.
Liquid Side O.D. 1/4 3/8
Refrigerant Pipe
Height Difference (Max.) 100
Ft.
Length (Max.) 100 165
Connection
Indoor/Outdoor Flared/Flared
Method
NOTES: Test conditions are based on ARI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.

28
INVERTER
PLA heat pump
(PLA-A36BA Model Shown
with optional I-SEE™ sensor)
P-Series Specifications

BS = Seacoast Protection
Indoor Unit PLA-A18BA PLA-A24BA PLA-A30BA PLA-A36BA PLA-A42BA
Model Name PUZ-A18NHA PUZ-A24NHA PUZ-A30NHA PUZ-A36NHA PUZ-A42NHA
Outdoor Unit
PUZ-A18NHA-BS PUZ-A24NHA-BS PUZ-A30NHA-BS PUZ-A36NHA-BS PUZ-A42NHA-BS
Rated Capacity Btu/h 18,000 24,000 30,000 35,000 42,000
Capacity Range Btu/h 8,000-18,000 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000
Total Input W 1,940 2,500 4,100 4,500 4,600
Cooling *1
Energy Efficiency SEER 14.2 13.6 14.2 14.4
Moisture Removal Pints/h 3.0 5.1 7.2 8.1 10.9
Sensible Heat Factor 0.81 0.76 0.73 0.74 0.71
Rated Capacity Btu/h 19,000 26,000 32,000 37,000 45,000
Capacity Range Btu/h 8,000-20,000 12,000-28,000 12,000-34,000 12,000-38,000 18,000-48,000
Heating at 47º F *2
Total Input W 1,900 2,570 3,370 3,300 4,450
HSPF (Region IV) Btu/h/W 9.8 8.5 8.7 9.3
Capacity Btu/h 13,000 16,000 23,000 25,000 30,000
Heating at 17º F *3
Total Input W 1,590 2,200 3,050 3,070 4,300
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Indoor - Outdoor S1-S2 AC 208-230V
Voltage Indoor - Outdoor S2-S3 DC24V
Indoor - Remote Controller DC12V : Wired Type
MCA A 1 2
Fan Motor F.L.A. 0.51 1.00
Fan Motor Output W 50 120
DRY (CFM) 420-490-570-640 490-570-640-740 710-810-920-1,060 780-880-990-1,090
Airflow (Lo-M1-M2-Hi)
WET (CFM) 390-460-530-600 460-530-600-710 670-770-880-1,030 740-850-950-1,060
External Pressure Pa 0
Sound Pressure Level
dB(A) 28-29-31-32 28-30-32-34 32-34-37-40 34-36-39-41
(Lo-M1-M2-Hi)
Indoor Unit
External Finish Color (Panel) Munsell No. 6.4Y 8.9/0.4
W: In. 33-1/16 (37-3/8)
Dimension Unit (Panel) D: In. 33-1/16 (37-3/8)
H: In. 10-3/16 (1-3/8) 11-3/4 (1-3/8)
Weight Unit (Panel) Lbs. 49 (13) 51 (13) 55 (13)
Drain Lift Mechanism
H: In. 33-7/16
(included)
Field Drainpipe Size O.D. In. 1-1/4
MCA A 13 18 25 26
MOCP A 15 30 40
Fan Motor F.L.A. 0.35 0.75 0.4 + 0.4
Fan Motor Output W 40 75 86 + 86
INVERTER-driven
Model (Type) DC INVERTER-driven Twin Rotary
Scroll
Compressor
R.L.A 12 20
L.R.A. 14 17.5 27.5
Airflow CFM 1,200 1,940 3,530
Refrigerant Control Linear Expansion Valve
Outdoor Unit
Defrost Method Reverse Cycle
Sound Pressure Level
dB(A) 46 48 51
(Cooling) *1
Sound Pressure Level
dB(A) 47 50 55
(Heating) *2
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 31-1/2 37-3/8
Dimensions D: In. 13 + 7/8 13 + 1-3/16
H: In. 23-5/8 37-1/8 53-1/8
Weight Lbs. 99 165 260
Remote Controller Type Wired Remote Controller Packaged with Grille
Type R410A
Refrigerant Charge Lbs., Oz. 3, 12 6 10
Oil Type (Fl. Oz.) MEL56 (20) MEL56 (28) FV50S (45)
Gas Side O.D. 1/2 5/8
In.
Refrigerant Pipe Liquid Side O.D. 1/4 3/8
Height Difference (Max.) 100
Ft.
Length (Max.) 100 165
Connection Method Indoor/Outdoor Flared/Flared
NOTES: Test conditions are based on ARI 210/240. *3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C). *4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Specifications are subject to change without notice.
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6.1º C). LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.

29
PCA
CEILING-SUSPENDED series
24,000 to 42,000 Btu/h Capacity

PCA Ind oor Unit


(The same indoor unit is used for both
cooling and heat pump systems.)

The PCA-Series is all about providing pow-


erful cooling and heating performance. This
ceiling-suspended unit delivers enough cold or
hot air to make any space more comfortable.
Manually-adjusted, over-sized swing louvers
direct the airflow left or right, quietly covering
the entire space. Accessory filters are available
to increase efficiency and increase the time
span between service calls. The PCA-Series
is perfect for restaurants, kitchens and other
larger commercial spaces where ovens and
other equipment add to an already taxed
cooling or heating load.

Control Airflow Angle


for Better Coverage
All Mr. Slim PCA-Series models
With the wired remote controller four different come with a wired remote controller
airflow positions can be set. When in use the that puts you in command of your
personal comfort. The wireless controller
Autovane during cooling, the angle self-adjusts
is available in an accessory kit.
into a horizontal position to circulate cold air
more effectively. During heating, the vane
directs the hot air downward toward the floor,
where it will rise and circulate, keeping your
room comfortable from top to bottom.
Bring In Outside Air
Ducting can be installed with minimal
Warm Air with No Drafts on-site work to bring in outside air,
creating a healthier indoor environment.
Mr. Slim P-Series heat pumps provide warmth
without drafts from the beginning with our
hot-start technology.
Automatic Cooling/heating Changeover
(Heat Pumps)
When set to AUTO mode, heat pump systems will automatically switch back
and forth between cooling and heating operation to compensate for indoor
and outdoor temperature fluctuations. This feature means total hands-free
comfort and efficient air conditioning of your space.

30
(PCA-A36GA Model Shown)

INVERTER
PCA COOLING-ONLY
P-Series Specifications
BS = Seacoast Protection
Indoor Unit PCA-A24GA PCA-A30GA PCA-A36GA PCA-A42GA
Model Name PUY-A24NHA PUY-A30NHA PUY-A36NHA PUY-A42NHA
Outdoor Unit
PUY-A24NHA-BS PUY-A30NHA-BS PUY-A36NHA-BS PUY-A42NHA-BS
Rated Capacity Btu/h 24,000 30,000 35,000 42,000
Capacity Range Btu/h 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000
Total Input W 2,500 4,100 4,630 5,070
Cooling *1
Energy Efficiency SEER 13.4 13.0 13.1 13.8
Moisture Removal Pints/h 5.4 8.3 8.2 11.7
Sensible Heat Factor 0.75 0.69 0.74 0.69
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208-230V *2
Indoor - Outdoor S1-S2 AC 208/230V
Voltage Indoor - Outdoor S2-S3 DC24V
Indoor - Remote Controller DC12V : Wired Type
MCA A 1
Fan Motor F.L.A. 0.53 0.69
Fan Motor Output W 70 90
DRY (CFM) 495-530-565-635 705-740-810-880
Airflow (Lo-M1-M2-Hi)
WET (CFM) 445-480-510-570 635-670-730-790
Sound Pressure Level
dB(A) 37-39-41-43 40-41-43-45
Indoor Unit (Lo-M1-M2-Hi)
External Finish Color Munsell No. 0.70Y 8.59/0.97
W: In. 51-9/16
Dimension Unit D: In. 26-3/4
H: In. 8-5/16 10-5/8
Weight Unit Lbs. 75 82
Field Drainpipe Size O.D. In. 1
MCA A 18 25 26
MOCP A 30 40
Fan Motor F.L.A. 0.75 0.4 + 0.4
Fan Motor Output W 75 86 + 86
INVERTER-driven
Model (Type) DC INVERTER-driven Twin Rotary
Scroll
Compressor R.L.A. 12 20
L.R.A. 14 17.5 27.5
Outdoor Unit Airflow CFM 1,940 3,530
Refrigerant Control Linear Expansion Valve
Sound Pressure Level (Cooling) *1 dB(A) 48 51
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 37-3/8
Dimensions D: In. 13 + 1-3/16
H: In. 37-1/8 53-1/8
Weight Lbs. 163 258
Remote Controller Type Wired Remote Controller (Located with Indoor Unit)
Type R410A
Refrigerant Charge Lbs. 6 10
Oil Type (Fl. Oz.) MEL56 (28) FV50S (45)
Gas Side O.D. 5/8
In.
Refrigerant Pipe Liquid Side O.D. 3/8
Height Difference (Max.) Ft. 100
Length (Max.) 165
Connection Method Indoor/Outdoor Flared/Flared

NOTES: Test conditions are based on ARI 210/240.


*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.

31
(PCA-A36GA Model Shown)

INVERTER
PCA Heat Pump
P-Series Specifications

BS = Seacoast Protection
Indoor Unit PCA-A24GA PCA-A30GA PCA-A36GA PCA-A42GA
Model Name PUZ-A24NHA PUZ-A30NHA PUZ-A36NHA PUZ-A42NHA
Outdoor Unit
PUZ-A24NHA-BS PUZ-A30NHA-BS PUZ-A36NHA-BS PUZ-A42NHA-BS
Rated Capacity Btu/h 24,000 30,000 35,000 42,000
Capacity Range Btu/h 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000
Total Input W 2,500 4,100 4,630 5,070
Cooling *1
Energy Efficiency SEER 13.4 13 13.1 13.8
Moisture Removal Pints/h 5.4 8.3 8.2 11.7
Sensible Heat Factor 0.75 0.69 0.74 0.69
Rated Capacity Btu/h 26,000 32,000 37,000 45,000
Capacity Range Btu/h 12,000-28,000 12,000-34,000 12,000-38,000 18,000-48,000
Heating at 47º F *2
Total Input W 2,570 3,390 3,490 4,850
HSPF (Region IV) Btu/h/W 8.5 8.3 8.5
Capacity Btu/h 16,000 23,000 25,000 30,000
Heating at 17º F *3
Total Input W 2,200 3,050 3,070 4,300
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Indoor - Outdoor S1-S2 AC 208-230V
Voltage Indoor - Outdoor S2-S3 DC24V
Indoor - Remote Controller DC12V : Wired Type
MCA A 1
Fan Motor F.L.A. 0.53 0.69
Fan Motor Output W 70 90
DRY (CFM) 495-530-565-635 705-740-810-880
Airflow (Lo-M1-M2-Hi)
WET (CFM) 445-480-510-570 635-670-730-790
Sound Level
dB(A) 37-39-41-43 40-41-43-45
Indoor Unit (Lo-M1-M2-Hi)
External Finish Color Munsell No. 0.70Y 8.59/0.97
W: In. 51-9/16
Dimension Unit D: In. 26-3/4
H: In. 8-5/16 10-5/8
Weight Unit Lbs. 75 82
Field Drainpipe Size O.D. In. 1
MCA A 18 25 26
MOCP A 30 40
Fan Motor F.L.A. 0.75 0.4 + 0.4
Fan Motor Output W 75 86 + 86
INVERTER-driven
Model (Type) DC INVERTER-driven Twin Rotary
Scroll
Compressor
R.L.A. 12 20
L.R.A. 14 17.5 27.5
Airflow CFM 1,940 3,530
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Level at Cooling *1 dB(A) 48 51
Sound Level at Heating *2 dB(A) 50 55
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 37-3/8
Dimensions D: In. 13 + 1-3/16
H: In. 37-1/8 53-1/8
Weight Lbs. 165 260
Remote Controller Type Wired Remote Controller (Located with Indoor Unit)
Type R410A
Refrigerant Charge Lbs. 6 10
Oil Type (Fl. Oz.) MEL56 (28) FV50S (45)
Gas Side O.D. 5/8
In.
Liquid Side O.D. 3/8
Refrigerant Pipe
Height Difference (Max.) Ft. 100
Length (Max.) 165
Connection Method Indoor/Outdoor Flared/Flared
NOTES: Test conditions are based on ARI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.

32
MS/MU,MSY/MUY,MSZ/MUZ/MXZ RATING CONDITIONS REFRIGERANT LINE LENGTH FLARE/FLARE
INDOOR INTAKE AIR OUTDOOR INTAKE AIR Max. Max.
TEMPERATURE TEMPERATURE Indoor Unit Outdoor Unit Length Height
in feet in feet
95º F D.B. (MS/MSY/MSZ), MS-A09WA MU-A09WA 65 35
90º F D.B. (MSY/MSZ-D/FD),
MAXIMUM 115º F D.B. MS-A12WA MU-A12WA 65 35
71º F W.B. (MS/MSY/MSZ),
COOLING 73º F W.B. (MSY/MSZ-D/FD) MSY-A15NA MUY-A15NA 65 40
MSY-A17NA MUY-A17NA 65 40
67º F D.B. (MU),
MINIMUM 67º F D.B., 57º F W.B. MSY-A24NA MUY-A24NA 100 50
14º F D.B. (MUY(Z), MXZ)
MAXIMUM 80º F D.B., 67º F W.B. 75º F D.B., 65º F W.B. MSZ-A09NA MUZ-A09NA 65 40
MSZ-A12NA MUZ-A12NA 65 40
HEATING 14º F D.B., 13º F W.B. (MUZ),
MINIMUM 70º F D.B., 60º F W.B. MSZ-A15NA MUZ-A15NA 65 40
12º F W.B. (MXZ)
MSZ-A17NA MUZ-A17NA 65 40
* MU units operate at intake air temperature down to 10º F with the addition of an ICM-326HM-1 low temperature control.
MSZ-A24NA MUZ-A24NA 100 50

PKA/PLA/PUZ-HA RATING CONDITIONS MSZ-FD09NA MUZ-FD09NA 65 40


MSZ-FD12NA MUZ-FD12NA 65 40
INDOOR INTAKE OUTDOOR INTAKE AIR
AIR TEMPERATURE TEMPERATURE MSY-D30NA MUY-D30NA 100 50
MAXIMUM 90º F D.B., 73º F W.B. 115º F D.B. MSY-D36NA MUY-D36NA 100 50
COOLING
MINIMUM 66º F D.B., 59º F W.B. 0º F D.B.* MSZ-D30NA MUZ-D30NA 100 50
MAXIMUM 83º F D.B. 70º F D.B., 59º F W.B. MSZ-D36NA MUZ-D36NA 100 50
HEATING MSZ-A09NA, MSZ-A12NA,
MINIMUM 63º F D.B. -13º F D.B., -13º F W.B. MXZ-2A20NA 164 49*/33
MSZ-A15NA
(* With wind baffle accessory installed) Without wind baffle installed, the minimum temperature will be 23º F D.B. MSZ-A09NA, MSZ-A12NA,
MSZ-A15NA, MSZ-A17NA, MXZ-3A30NA 230 49*/33
PKA/PLA/PCA/PUY/PUZ-A RATING CONDITIONS MSZ-A24NA
MSZ-A09NA, MSZ-A12NA,
INDOOR INTAKE AIR OUTDOOR INTAKE AIR MSZ-A15NA, MSZ-A17NA, MXZ-4A36NA 230 49*/33
TEMPERATURE TEMPERATURE MSZ-A24NA
MAXIMUM 95º F D.B., 71º F W.B. 115º F D.B. PKA-A12GA (L) PUY-A12NHA 100 100
COOLING PUY-A18NHA,
MINIMUM 67º F D.B., 57º F W.B. 0º F D.B.* PKA-A18GA (L) 100 100
PUZ-A18NHA
MAXIMUM 80º F D.B., 67º F W.B. 70º F D.B., 59º F W.B. PUY-A24NHA,
HEATING PKA-A24FA (L) 165 100
MINIMUM 70º F D.B., 60º F W.B. 12º F D.B., 10º F W.B. PUZ-A24NHA
(* With wind baffle accessory installed) Without wind baffle installed, the minimum temperature will be 23º F D.B. PUY-A30NHA,
PKA-A30FA (L) 165 100
PUZ-A30NHA
REFRIGERANT TUBING SETS PUY-A36NHA,
PKA-A36FA (L) 165 100
PUZ-A36NHA
Lineset
Tube Length Use With Mitsubishi Electric PKA-A36FA (L) (H2i) PUZ-HA36NHA 265 100
Model Insul.
Size (In.) Ft. Mr. Slim Models
Number PLA-A12BA PUY-A12NHA 100 100
MLS143812T-15 1/4 x 3/8 15 1/2"
PUY-A18NHA,
MLS143812T-30 1/4 x 3/8 30 1/2" MS-A09WA; MSZ-A09NA, MSZ-A12NA; PLA-A18BA 100 100
PUZ-A18NHA
MLS143812T-50 1/4 x 3/8 50 1/2" MSZ-FD09NA, MSZ-FD12NA
PUY-A24NHA,
MLS143812T-65 1/4 x 3/8 65 1/2" PLA-A24BA 165 100
PUZ-A24NHA
MLS141212T-15 1/4 x 1/2 15 1/2"
MS-A12WA; MSY-A15NA, MSY-A17NA, PUY-A30NHA,
MLS141212T-30 1/4 x 1/2 30 1/2" PLA-A30BA 165 100
MSZ-A15NA, MSZ-A17NA; PUZ-A30NHA
MLS141212T-50 1/4 x 1/2 50 1/2"
PKA-A12GA(L), PKA-A18GA(L); PUY-A36NHA,
MLS141212T-65 1/4 x 1/2 65 1/2" PLA-A36BA 165 100
PLA-A12BA, PLA-A18BA PUZ-A36NHA
MLS141212T-100 1/4 x 1/2 100 1/2"
PLA-A36BA (H2i) PUZ-HA36NHA 265 100
MLS145812T-15 1/4 x 5/8 15 1/2"
PUY-A42NHA,
MLS145812T-30 1/4 x 5/8 30 1/2" PLA-A42BA 165 100
PUZ-A42NHA
MLS145812T-50 1/4 x 5/8 50 1/2" MSY-A24NA, MSZ-A24NA
MLS145812T-65 1/4 x 5/8 65 1/2" PUY-A24NHA,
PCA-A24GA 165 100
PUZ-A24NHA
MLS145812T-100 1/4 x 5/8 100 1/2"
MPLS385812T-10 3/8 x 5/8 10 1/2" MSY-D30NA, MSZ-D30NA, PUYA30NHA,
PCA-A30GA 165 100
MPLS385812T-15 3/8 x 5/8 15 1/2" MSY-D36NA, MSZ-D36NA; PUZA30NHA
MPLS385812T-30 3/8 x 5/8 30 1/2" PKA-A24FA(L), PKA-A30FA(L), PKA-A36FA(L);
PUYA36NHA,
MPLS385812T-50 3/8 x 5/8 50 1/2" PLA-A24BA, PLA-A30BA, PLA-A36BA, PCA-A36GA 165 100
PUZA36NHA
PLA-A42BA; PCA-A24GA,
MPLS385812T-65 3/8 x 5/8 65 1/2" PCA-A30GA, PCA-A36GA, PUYA42NHA,
MPLS385812T-100 3/8 x 5/8 100 1/2" PCA-A42GA PCA-A42GA 165 100
PUZA42NHA
*49' applies to installations in which the outdoor unit is installed below indoor unit.

33
OPTIONAL ACCESSORIES
PART NUMBER USE WITH DESCRIPTION
Controls Options
MAC-397IF-E M-Series Inverter Units MA and contact terminal interface
MAC-399IF-E M-Series Inverter Units M-NET control adapter for Mr. Slim MSY and MSZ models
PAC-725AD P-Series Connector for CN51/multiple remote controller adapter and duct fan controller
PAC-715AD P-Series Connector for CN32 (For remote ON/OFF)
PAC-SE41TS-E P-Series Remote temperature sensor for indoor units
PAC-SA1ME-E PLA-ABA i-see™ sensor corner panel for PLA-ABA indoor units
PAC-SF40RM-E P-Series Remote operation adapter: display and ON/OFF
PAC-SF80MA-E P-Series M-NET control adapter for Mr. Slim PUY-A, PUZ-A, and PUZ-HA Models
PAC-SK52ST P-Series Control / service tool
PAR-21MAA-G Use for wired M-Series Controller Deluxe MA remote controller (Requires MAC-397IF-E)
PAR-SL99U-E PCA Wireless remote controller kit for PCA suspended units
PAR-FA32MA-E PLA-ABA Wireless remote controller for PLA-ABA units (Requires signal receiver PAR-SA9FA-E)
PAR-SA9FA-E PLA-ABA Wireless signal receiver for PLA-ABA units (For PAR-FA32MA-E controller)
PZ-41SLB-E Lossnay® Lossnay ERV remote controller for LGH ERV control
Low Ambient
WB-PA1 P-Series Wind baffle (1 piece) PUY/Z-A12/A18
WB-PA2 P-Series Wind baffle (1 piece) PUY/Z-A24/A30/A36/A42 (42 installation requires 2 pieces); PUZ-HA36NA (Requires 2 pieces)
ICM-326HM-1 M-Series Non-Inverter units Low ambient head pressure controller
Filters
MAC-2300FT M-Series Indoor Unit - A24 Anti-allergy enzyme filter
MAC-415FT M-Series Indoor Unit - A09/A12/A15/A17 Anti-allergy enzyme filter
MAC-418FT MSZ-FD09/12 Anti-allergy enzyme filter
MAC-308FT MSZ-FD09/12 Platinum deodorizing filter
MAC-1415FT-E M-Series Indoor Unit - D30/36 Anti-allergy enzyme filter
PAC-SE81KF-E PCA High-efficiency (MERV 10) filter element
PAC-SH59KF-E PLA-ABA High-efficiency (MERV 10) filter element (Requires PAC-SH53TM-E multi-function casement)
Pumps
SI1730-230 P-Series Mini-condensation pump: 230V
SI3100-115 MS-Series Mini-condensation pump: 115V
SI3100-230 MSY/Z-Series Mini-condensation pump: 230V
Miscellaneous
TAZ-MS303 M-Series and P-Series Three-pole disconnect switch; 30A, 600V; turns off power between indoor and outdoor units
CWMB1 MU and PU outdoor units Condensing unit wall mounting brackets: painted steel
PAC-SH53TM-E PLA-ABA Multi-function casement (High-efficiency filter element not included)
PAC-SH51SP-E PLA-ABA Air outlet shutter plates (1 set = 2 pieces)
PAC-SG58SG-E P-Series Air outlet guide (1 piece) PUY/Z-A12/A18
PAC-SG59SG-E P-Series Air outlet guide (1 piece) PUY/Z-A24/A30/A36/A42 (42 installation requires 2 pieces); PUZ-HA36NA (Requires 2 pieces)
PAC-SG61DS-E P-Series Drain socket
MAC-851DS MUZ-FD09/12 Drain socket
MAC-811DS MUY(Z)-D30/36 Drain socket assembly
PAC-SG63DP-E PUY(Z)-A12/18 Drain pan
PAC-SG64DP-E PUY(Z)-A24/30/36/42 and PUZ-HA36 Drain pan
RCMKP1CB M and P Series Wireless Lockdown bracket for wireless remote controller
ULTRILITE1 All M-Series and PUZ(Y)-A12/18 Condensing unit mounting pad: 16" x 36" x 3"
ULTRILITE2 PUY(Z)-A24/30/36/42; PUZ-HA36 Condensing unit mounting pad: 24" x 42" x 3"
Port Adapters
MAC-A454JP-E MXZ-Series Adapter: 3/8" x 1/2"
MAC-A455JP-E MXZ-Series Adapter: 1/2" x 3/8"
MAC-A456JP-E MXZ-Series Adapter: 1/2" x 5/8"
PAC-493PI MXZ-Series Adapter: 1/4" x 5/8"
PAC-SG76RJ-E MXZ-Series Adapter: 3/8" x 5/8"
MSDD-50SR-E P-Series Distribution pipe
PAC-SC84PI-E PKA-Series (A24/30/36/42) L-connector pipe (for left-side piping)

34
LLineset
ine - Hide
TM

Cover System
Put a professional finish on air conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects linesets, drainlines, and wiring.
• Available in four sizes: 2-1/4”, 3”, 4”, and 6” tubes.
• Snap-on covers and a full selection of couplings,
elbows, T-joints, caps, and more for any application,
complex or simple.
• High-quality PVC with UV inhibitors for outdoor
service in all weather conditions.
• Can be painted with most house paints to match
exterior decors.
• Not just for HVAC. Hide any exterior cabling, piping,
or wiring.
• Use it indoors, too! Meets UL94v-0 for interior
applications.
Download a brochure at www.mrslim.com to find out
more information.

BV-Series Ball Valves


Model numbers:
BV14FFSI
BV38FFSI C US
BV12FFSI LISTED 891N
REFRIGERANT
BV58FFSI VALVE • Engineered for Mini-split and
Multi-split HVAC Units
• Size available: 1/4”; 3/8”; 1/2”; 5/8”
• Fully factory assembled
• Full Port Design
• Furnace brazed and pressure tested • 700 PSIG Rated
• Each ball valve is equipped with Schrader Valve
for refrigerant service • R-410A Compatible
• Design working pressure: 700 PSIG
• Temperature range: • Flare Connections
-40˚ F to +325˚ F (-40˚ C to +149˚ C)
• Forged brass body and seal cap SAE
Part Number A B C D E F
• Teflon® seals and gaskets (no synthetic O-rings) Flare
• Seal cap design permits valve operation without BV14FFSI 1/4” 6.19 2.60 1.80 1.22 1.42 1.10
removal of seal cap
• Suitable for use with R-11, R-22, R-123, R-125, BV38FFSI 3/8” 6.30 2.67 1.80 1.22 1.42 1.10
R-134A, R-236FA, R-4202A, R-402B, R-404A, BV12FFSI 1/2” 6.51 2.67 1.80 1.22 1.42 1.10
R-407C, R-410A, R-500, R-502, and R-507 BV58FFSI 5/8” 6.64 2.67 1.80 1.28 1.42 1.10
• One year limited materials and workmanship *ball valves come with an insulation piece
warranty on Ball Valves
35
Provides personalized comfort control for every room.

Mitsubishi Electric Shizuoka Works acquired


ISO 9001 certification under Series 9000 of the
International Standard Organization (ISO), based on
a review of quality warranties for the production of
air-conditioning equipment. The plant also acquired
environmental management system standard ISO
14001 certification.

Mitsubishi Electric Advanced Products Division


3400 Lawrenceville Suwanee Road
49385

Suwanee, GA 30024
Phone: 888-467-7546 Fax: 800-658-1458
EC 97J1132
©2008 Mitsubishi Electric & Electronics USA, Inc. Mr Slim is a registered trademark, and H2i
is a trademark of Mitsubishi Electric. The three-diamond logo is a registered logo of Mitsubishi
Electric Corporation.
*Hyper-Heating technology Patent Pending.
See complete warranty for terms, conditions and limitations. A copy is available from Mitsubishi Electric.

Form No. MBROGEN-10-08-30M-v2 PD


For more information visit www.mrslim.com

You might also like