Mr. Slim® Split-ductless Systems: Redefining Comfort
Comfort is a concept many of
us notice only when we’re
either uncomfortable or very
relaxed. But at Mitsubishi
Electric HVAC Advanced
Products Division, all we
think about is comfort. Our
industry-leading Mr. Slim
split-ductless cooling and
heating systems reflect this
thinking. At home or at work
our Mr. Slim systems are
designed to make any space
inviting and comfortable.
02
Good for the environment and your bottom line.
• Eco-friendly refrigerant: Environmentally-friendly R410A refrigerant offers zero Ozone Depletion
Potential (ODP) and allows for higher heat transfer coefficient (COP). This innovative feature means a
reduction in equipment size, a reduction in piping size and higher pressure for greater performance.
Smaller equipment also means less impact on the environment at the end of the product’s life cycle.
• Standard compliance: All Mitsubishi Electric HVAC products follow standards and guidelines as set
forth by the Energy Star, EPA, ARI, UL, ASHRAE, ETL and ISO.
• Recycling design: Our air conditioners are specially designed to allow for easy cleaning, efficient
disassembly and more practical recycling. The number of parts used in indoor units has been reduced
by adopting modular components, a process which also simplifies materials separation for recycling.
To date as much as 84 percent of the materials used to build a Mr. Slim system is recyclable.
• Smart energy usage: Mitsubishi Electric INVERTER zoning systems smartly deliver only the amount
of capacity needed unlike a typical full-power ON system. Individual indoor air handlers are installed
within the zone. These air handlers measure the load for that specific zone and deliver for added
efficiency only the capacity needed directly to the space, as compared to energy lost in long duct
runs. If the zone is not being used, you do not have to condition the space. Smarter sensing
technology and microprocessors enhance the system’s ability to measure room temperature
accurately for added comfort, performance and efficiency.
• Minimal impact on landfills: All air-conditioning products use long-life washable filters.
03
Where Can Mr. Slim Products Be Used?
Mr. Slim split-ductless systems are specifically designed to improve the
comfort level in an uncomfortably hot or cold room of an existing building.
Because Mr. Slim Systems do not require ductwork, they are the perfect
cooling and heating systems for renovating older buildings – even those with
plaster walls and brick facades that were constructed before air conditioning
was available. The versatility and variety of applications for Mr. Slim systems
are virtually unlimited. They’re an excellent choice for almost any spot-cooling
or heating situation, including enclosed sunrooms, upstairs bedrooms,
new additions, bonus rooms, finished basements, classrooms, hospitals,
nursing homes, restaurants, hotels, workout rooms, computer rooms,
offices and churches.
Mr. Slim systems work hard for you even in extreme temperatures, maintaining
a toasty, warm environment even when it’s as cold as -13o F outside with the
Hyper-Heating INVERTER (H2i™) P-Series system. Mr. Slim systems are also
equipped with an anti-allergen filter that helps prevent the circulation of air with
contaminants. And because the indoor units can be controlled by zone, it is
easy to set the controls for the exact room temperature you want within
any given space.
04
G l o ss a r y INDEX
Air conditioner: A mechanical device used to INVERTER TECHNOLOGY: Pages 06-07
control temperature and air movement in a
confined space. M-Series: 9,000-36,000 Btu/h
Btu/h (British Thermal Units per Hour): A measure Residential and Select Commercial Applications
of cooling or heating capacity.
Capacity or Load: A refrigeration rating system Overview of Product Line
usually measured in Btu/h. Pages 08 - 09
05
INVERTER
INVERTER-DRIVEN COMPRESSOR TECHNOLOGY
INVERTER
Neodymium
magnets
INVERTER-driven Compressor
(not shown to scale)
06
INVERTER
MSZ-A12 Indoor Unit
MSZ-A12 Indoor Unit
07
M-Series
residential AND select commercial
08
M -Seri es M SY(Z)-D30N A M o del Indoor U ni t
Features Benefits
INVERTER Maximizes energy savings by making sure only the energy
Technology needed to cool or heat an area is used.
convenient wireless Offers comfort control in the palm of your hand with
remote control our remote controller
washable long-life Improves air quality and saves money by being washable
anti-allergen filters rather than replaceable
09
M-SERIES WALL-MOUNTED A/C LINEUP
(c ooling only ) NEW Large Capacity
MSY( Z ) -D 3 0 / 3 6 NA
M S Non- INVER TER MSY I N V E RT E R I N V E R T E R A i r C o n d itioners
A ir Cond itione r s Ai r C o n d i t i o n e r s a n d H e a t Pu m ps
M-S e ries Wireless 9, 500 to 12, 000 B tu/ h 1 5 , 0 0 0 t o 3 4 , 6 0 0 Bt u / h 3 0 , 7 0 0 t o 3 4 , 6 0 0 Bt u / h
Re m o te Con troller [ p g. 12] [pgs. 12 - 13] [pgs. 14 - 15]
Multiple Filters for Cleaner, Standard filter system (MS(Y)-D30NA Model Shown)
Healthier Air
Mr. Slim M-Series indoor units use a sophisticated multipart Front Panel
filter system to remove contaminants such as allergens,
viruses and bacteria from the air as it circulates.
Hybrid Catechin
The hybrid catechin filter absorbs odor-causing gases. A pre-filters
blue-enzyme anti-allergen filter reduces germs, bacteria
Blue Enzyme
and viruses and helps trap dust, pollens, mites and Anti-allergen filter
other particles; the filter uses an enzyme catalyst to help
break down the sulfur atom bonds in allergen proteins,
transforming them into non-allergen proteins.
Energy Efficiency
Hybrid Catechin
MSZ-FD09/12NA systems produce the highest ductless
pre-filters
system ratings in the industry at 23 SEER while being
extremely quiet at a low 22dB(A) for the indoor unit. Platinum Catalyst
Deodorizing filter
The increased energy efficiency, up to 35 percent over
standard Mr. Slim M-Series systems and 70 percent Blue Enzyme
over industry standard requirement of 13 SEER, is a Anti-allergen filter
result of a new powerful magnet rotor that allows for
lower current input. With the increased energy
efficiency and SEER ratings the MSZ-FD models
are ENERGY STAR® Tier 2 certified.
10
M-SERIES WALL-MOUNTED HEAT PUMP LINEUP
NEW Up to 23 SEER (c ooling a n d h e a t i n g )
MSZ-FD 0 9 / 1 2 N A M SZ I N V E RT E R MX Z Mu l t i -Z o n e
High- Ef f ic ie nc y H e a t Pu m p s I N V E RT E R
INVERTER He a t P ump s 9, 00 0 t o 3 3 , 2 0 0 Bt u / h H e a t Pu m ps
9,0 00 an d 12, 000 B tu/ h [pgs. 14 - 15] 2 0 , 0 0 0 t o 3 6 , 0 0 0 Bt u / h
[pg. 14]
[pgs. 16 - 17]
With the WIDE VANE or SWING mode, The i-see sensor detects the always troublesome regions of
available on the MSY(Z)-A24/D30/36NA, temperature closer to the ceiling and the floor. The i-see sensor
there is an option for seven horizontal airflow also controls the airflow up to a wide 150˚ lateral angle for ultimate
directions that provide 150 degrees of airflow comfort (90˚ angle in cooling mode) by scanning the room and
for greater conditioned air circulation. making adjustments based on the ambient temperature readings.
Through this process the MSZ-FD09/12NA systems achieve superior
cooling/heating performance with extremely efficient operation.
Quiet Operation
Do you hear that? No? You barely hear
Multi-zone Heat Pump
our systems because Mr. Slim indoor units System Attributes
operate with nearly a whisper of sound. A
Multi-zone systems mean that people can enjoy their ideal level of
police siren, for example, has a sound level
comfort no matter where they are in the home. Each zone operates
of 118 decibels; a circular saw produces 107
independently. People in the kitchen, master bedroom or living
decibels of sound. A vacuum cleaner in your
room can all enjoy the temperatures that makes them feel most
home creates 74 decibels of noise. Even a
comfortable.
library environment is at 33 decibels while
a whisper-tone voice produces 35 decibels. If you’re looking for a complete comfort solution for several different
Certain Mr. Slim units operates as low as 22 rooms, the MXZ multi-zone system is the right choice for you. You
decibels in low speed and others range from can use up to 19 different indoor unit combinations so the system
26 to 34 decibels in low speed, all lower than is flexible enough to conform to your particular cooling and heating
a whisper-tone voice. needs with up to four rooms from one outdoor unit.
11
(MS-A12WA Model Shown)
ms/msy COOLING-ONLY
m-Series Specifications
INVERTER
Non-inverter
Indoor Unit MS-A09WA MS-A12WA MSY-A15NA MSY-A17NA
Model Name
Outdoor Unit MU-A09WA MU-A12WA MUY-A15NA MUY-A17NA
Rated Capacity Btu/h 9,500 12,000 15,000 16,200
Capacity Range Btu/h - - 3,100-15,000 3,100-16,200
Cooling *1 Total Input W 870 1,070 1,690 (210-1,690) 2,070 (210-2,070)
Energy Efficiency SEER 13 16
Moisture Removal Pints/h 2.7 3.2 4.7 5.1
Sensible Heat Factor 0.68 0.70 0.65
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 115V *2 1 Phase, 60Hz, 208/230V *2
Indoor - Outdoor L1 N / S1-S2 AC 115V AC 208-230V
Voltage Indoor - Outdoor L2 / S2-S3 AC 115V DC12-24V
Indoor - Remote Controller Wireless Type Wireless Type (Optional Wired Controller: DC12V)
MCA A 1.2 1.0
Fan Motor F.L.A. 0.95 0.76
DRY (CFM) 183-261-335 222-286-406 268-328-381
Airflow (Lo-Med-Hi)
WET (CFM) 162-233-300 198-254-363 240-293-342
Sound Pressure Level
dB(A) 26-32-40 33-38-45 34-40-45 34-40-46
(Lo-Med-Hi)
Indoor Unit External Finish Color Munsell No. 1.0Y 9.2/0.2 Munsell No. 1.0Y 9.2/0.2
W: In. 30-11/16 30-11/16
Dimension Unit D: In. 8-1/4 8-1/4
H: In. 11-3/4 11-3/4
Weight Unit Lbs. 23 23
Field Drainpipe Size O.D. In. 5/8 5/8
MCA A 14 16 14
Max. Fuse Size (Time Delay) A 15 20 15
Fan Motor F.L.A. 0.63 0.93 0.52
Model (Type) Single Rotary DC INVERTER-driven Twin Rotary
Compressor R.L.A. 9.3 10.82 10.1
L.R.A. 47 56 12
Airflow CFM 1,083 1,327 1,249
Outdoor Unit
Refrigerant Control Capillary Tube Linear Expansion Valve
Sound Pressure Level
dB(A) 47 52 50 52
(Cooling) *1
External Finish Color Munsell No. 3Y 7.8/1.1 Munsell No. 3Y 7.8/1.1
W: In. 31-1/2 33-7/16 31-1/2
Dimensions D: In. 11-1/4 11-7/16 11-1/4
H: In. 21-5/8 23-13/16 21-5/8
Weight Lbs. 78 96 88
Remote Controller Type Wireless Remote Wireless Remote (Optional Wired Controller)
Type R410A R410A
Refrigerant Charge Lbs., Oz. 2, 5 3, 1 2, 7
Oil Type (Fl. Oz.) NE022 (10.8) NE022 (15.2)
Gas Side O.D. In. 3/8 1/2 1/2
Liquid Side O.D. 1/4 1/4
Refrigerant Pipe
Height Difference (Max.) Ft. 35 40
Length (Max.) 65 65
Connection Method Indoor/Outdoor Flared/Flared Flared/Flared
12
(MS-A12WA Model Shown) INVERTER
msy COOLING-ONLY (cont.)
m-Series Specifications
13
(MSZ-FD12NA Model Shown) INVERTER
MSZ heat pump
m-Series Specifications
14
(MSY(Z)-D30NA Model Shown)
INVERTER
MSZ heat pump (cont.)
m-Series Specifications
15
MXZ-Multi INVERTER heat pump
m-Series Specifications
(MSZ-A12NA Model Shown)
INVERTER
MXZ-3A30NA Combinations
16
MXZ-2A20 NA (2:1) MXZ-3A30 NA ( 3 : 1 , 2 : 1 )
Outdoor Unit Outdoor Uni t
M SZ-A12N A
MSZ-A09NA + MSZ-A09NA 9,000 9,000 9,000 9,000 36,000 3,820 18.55 16.78
16.0 8.5 1/2 X 3/8” (1) MAC-A455JP-E
+ MSZ-A09NA + MSZ-A09NA 9,000 9,000 9,000 9,000 36,000 3,100 15.05 13.61
MSZ-A09NA + MSZ-A09NA 8,300 8,300 8,300 11,100 36,000 3,820 18.55 16.78
16.0 8.5 1/2 X 3/8” (1) MAC-A455JP-E
+ MSZ-A09NA + MSZ-A12NA 8,300 8,300 8,300 11,100 36,000 3,100 15.05 13.61
MSZ-A09NA + MSZ-A09NA 7,700 7,700 7,700 12,900 36,000 3,820 18.55 16.78
16.0 8.5 N.A.
+ MSZ-A09NA + MSZ-A15NA 7,700 7,700 7,700 12,900 36,000 3,100 15.05 13.61
MSZ-A09NA + MSZ-A09NA 7,700 7,700 10,300 10,300 36,000 3,820 18.55 16.78
16.0 8.5 1/2 X 3/8” (1) MAC-A455JP-E
+ MSZ-A12NA + MSZ-A12NA 7,700 7,700 10,300 10,300 36,000 3,100 15.05 13.61
17
P-Series
Commercial, institutional
AND large residential
Inverter-driven
Low Ambient Operation you’ll get.
compressor INVERTER
technology
gives Mr. Slim systems a
The ability of these units to operate
effectively in low temperatures along
Installation Service
higher degree of cooling and heating abilities with the addition of a low-ambient wind and Maintenance Ease
that outperform and manage energy more baffle accessoryallows for a space to be
efficiently than conventional systems. P-Series outdoor units are designed
air-conditioned even when it is as low
Desired room temperature is reached more with easy service and maintenance
as 0˚ F outside. This cooling ability is
quickly and maintained more consistently. in mind. Maintenance points are
important when dealing with electronic
This capability eliminates the peaks and located behind easy-access panels
equipment rooms, telecom substations,
valleys of temperature swings that we’re to make installation and service
surveillance mechanical rooms, restaurant
used to with conventional units. effortless for a trained technician. Four-
kitchens, fitness centers and more.
way piping access allows connection in
The PKA and PLA indoor units can be used four directions: front, rear, right and
with our Hyper-Heating INVERTER (H2i™) Redi-charged Systems bottom (all PUY/PUZ models). Using only
outdoor heat pump units. These innovative three polarity sensitive wires plus a ground
H2i outdoor units are designed to deliver P-Series outdoor units come with conductor run from the outdoor to the
consistent, efficient cooling and heating enough refrigerant to be installed indoor unit, providing both power and
even in extreme low outdoor temperatures 70 feet (PUY(Z)12-36) and up to 100 communication connections. Two non-
from a single INVERTER-driven feet (PUY(Z)42) from the indoor units. polar wires connect the indoor unit and
compressor system. Linesets can be run up to 100 feet from wall-mounted controller. This wiring design
PUY(Z)12-18 outdoor units and 165 feet helps avoid installation errors. An optional
from PUY(Z)24-42 outdoor units when
Flexible Control additional charge is added. Thanks to
wireless remote controller kit is available
for the P-Series ceiling-mounted
unique design profiles and R410A refriger- indoor units.
Convenient and efficient zone control means
ant, these systems are easier to fit into any
you can cool or heat only the spaces in use.
space. R410A is environmentally friendly
You can even have single or dual control-
with zero Ozone Depletion Potential (ODP).
lers connected to one system. The controller
18
Features Benefits
INVERTER You can enjoy high-speed cooling and heating
Technology and consistent delivery of comfort year-round.
Quiet operation
You can hold a board meeting or teach a class
in quiet comfort.
SET TEMPERATURE
TIMER MENU
ON/OFF
More Compact Inverter-driven Outdoor Units
FAN SPEED
MODE
FILTER These Mr. Slim units employ advanced Pulse Amplitude Modulation
TEST RUN
(PAM). PAM adjusts the form of the current wave to emulate the
SET TIME
CHECK
form of the supply voltage wave so that 98 percent of input
power is effectively utilized.
AIRFLOW UP/DOWN
PUZ-HA
TIMER ON/OFF
LOUVER PUY/PUZ
VENTILATION
(MULTILINGUAL)
19
H2i
TM
20
(Figure 1)
PKA
Warm Air Quickly! The PKA indoor unit is a compact
At startup a special circuit quickly delivers refrigerant to and quiet wall-mounted unit that delivers exceptional
the air-conditioning cycle. This process rapidly increases cooling and heating performance.
the mass flow rate in the system. As a result air at • Hard-wired, wall-mounted, remote controller
comfortable temperatures begins flowing from indoor (-FA model) or wireless (-FAL model)
units right away. Even at an outdoor temperature of -13˚ F, • Adjustable vane control
the H2i system can discharge 100˚ F temperature air from • Easy-clean filters
the indoor units. At 5˚ F outdoor temperature and above, the
discharge temperature reaches an impressive 110˚ F with a PLA
40˚ F temperature rise (see Figure 2). This feature translates PLA-A**-BA ceiling-recessed
into a comfortable climate in all zones of a home or office, indoor unit offers increased application flexibility
and ease of installation especially in tight spaces.
whether cooling or heating, no matter the
• Independent vane motor control: five fixed settings
temperature outside.
plus swing
• Auto wave airflow in heating mode: unit independently
cycles through all vertical positions for a more even
heat distribution
• Built-in drain lift mechanism for condensate removal; lifts
up to 33-7/16 in.
• Ventilation air intake
• Easy-clean filters
• Optional i-see™ sensor accessory
(Figure 2)
21
Two in One
If you have a large space such as a long room
or hallway which would be considered one
zone, two indoor units can be connected to
the outdoor unit to cool or heat the space and
provide the maximum amount of comfort. The
process in which two indoor units act as one to
spread the outdoor unit’s capacity over a large
area is called Twinning.
Indoor Room
Outdoor Unit
Heating Performance
at Low Temperatures
Our Hyper-Heating INVERTER system provides
outstanding heating performance at extremely
low temperatures while keeping effective energy
usage at the forefront. Take a look at these
impressive COP (Coefficient of Performance)
values. The Mr. Slim H2i P-Series systems are
able to maximize efficiency at low temperatures
while providing tremendous heating output.
H2i
COP PKA PLA
47˚ F 3.59 3.45
17˚ F 2.10 2.10
5˚ F 1.90 1.90
22
INVERTER
H2i Heat pump
TM
P-Series Specifications
NOTES:
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19.4º C); *3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); *5 Indoor units receive power
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C). Outdoor: D.B. 17º F (-8º C ), W.B. 15º F (-9º C ). from outdoor units through
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); *4 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); field-supplied interconnected
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C). Outdoor: D.B. 5º F (-15º C), W.B. 5º F (-15º C). wiring.
LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.
23
pkA
(GA/GAL,fA/FAl)
Wall-mounted series
12,000 to 34,200 Btu/h
Capacity
24
(PKA-A30FA Model Shown)
INVERTER
PKA COOLING-ONLY
P-Series Specifications
GA/FA = Wired controller
GAL/FAL = Wireless controller
BS = Seacoast Protection
PKA-A12GA PKA-A18GA PKA-A24FA PKA-A30FA PKA-A36FA
Indoor Unit
PKA-A12GAL PKA-A18GAL PKA-A24FAL PKA-A30FAL PKA-A36FAL
Model Name
PUY-A12NHA PUY-A18NHA PUY-A24NHA PUY-A30NHA PUY-A36NHA
Outdoor Unit
PUY-A12NHA-BS PUY-A18NHA-BS PUY-A24NHA-BS PUY-A30NHA-BS PUY-A36NHA-BS
Rated Capacity Btu/h 12,000 18,000 24,000 30,000 34,200
Capacity Range Btu/h 6,000-12,000 8,000-18,000 12,000-24,000 12,000-30,000 12,000-34,200
Total Input W 1,210 2,240 2,650 4,400 5,030
Cooling *1
Energy Efficiency SEER 13.8 14.1 13.5 13.0 13.1
Moisture Removal Pints/h 1.5 4.8 4.7 8.1 7.1
Sensible Heat Factor 0.86 0.70 0.78 0.70 0.77
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Indoor - Outdoor S1-S2 AC 208-230V
Indoor - Outdoor S2-S3 DC24V
Voltage
Indoor - Remote Controller DC12V : Wired Type (GA/FA)
Indoor - Remote Controller Wireless Type (GAL/FAL)
MCA A 1
Fan Motor F.L.A. 0.33 0.43 0.52
Fan Motor Output W 30 45 70
Airflow (Lo-M1-M2-Hi) or DRY (CFM) 320-350-390-425 530-705 780-990
(Lo-Hi) WET (CFM) 290-315-350-380 480-635 700-890
Sound Pressure Level
dB(A) 36-38-41-43 39-45 46-49
(Lo-M1-M2-Hi) or (Lo-Hi)
Indoor Unit
External Finish Color Munsell No. 0.70Y 8.59/0.97 Munsell No. 3.4Y 7.7/0.8
W: In. 39 55-1/8 66-1/8
Dimension Unit D: In. 9-1/4
H: In. 13-3/8
Weight Unit Lbs. 35 53 62
Field Drainpipe Size I.D. In. 13/16
MCA A 13 18 25
MOCP A 15 20 30 40
Fan Motor F.L.A. 0.35 0.75
Fan Motor Output W 40 75
Model (Type) DC INVERTER-driven Twin Rotary
Compressor R.L.A 12
L.R.A. 14 17.5
Airflow CFM 1,200 1,940
Outdoor Unit Refrigerant Control Linear Expansion Valve
Sound Pressure Level
dB(A) 46 48
(Cooling) *1
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 31-1/2 37-3/8
Dimensions D: In. 13 + 7/8 13 + 1-3/16
H: In. 23-5/8 37-1/8
Weight Lbs. 90 97 163
Remote Controller Type GA/FA = Wired; GAL/FAL = Wireless (Located with Indoor Unit)
Type R410A
Refrigerant Charge Lbs., Oz. 2, 14 3, 12 6
Oil Type (Fl. Oz.) MEL56 (20) MEL56 (28)
Gas Side O.D. 1/2 5/8
In.
Liquid Side O.D. 1/4 3/8
Refrigerant Pipe
Height Difference (Max.) 100
Ft.
Length (Max.) 100 165
Connection Method Indoor/Outdoor Flared/Flared
25
(PKA-A30FA Model Shown)
INVERTER
PKA HEAT PUMP
P-Series Specifications
GA/FA = Wired controller
GAL/FAL = Wireless controller
BS = Seacoast Protection
PKA-A18GA PKA-A24FA PKA-A30FA PKA-A36FA
Indoor Unit
PKA-A18GAL PKA-A24FAL PKA-A30FAL PKA-A36FAL
Model Name
PUZ-A18NHA PUZ-A24NHA PUZ-A30NHA PUZ-A36NHA
Outdoor Unit
PUZ-A18NHA-BS PUZ-A24NHA-BS PUZ-A30NHA-BS PUZ-A36NHA-BS
Rated Capacity Btu/h 18,000 24,000 30,000 34,200
Capacity Range Btu/h 8,000-18,000 12,000-24,000 12,000-30,000 12,000-34,200
Cooling *1 Total Input W 2,240 2,650 4,400 5,030
Energy Efficiency SEER 14.1 13.5 13 13.1
Moisture Removal Pints/h 4.8 4.7 8.1 7.1
Sensible Heat Factor 0.70 0.78 0.70 0.77
Rated Capacity Btu/h 19,000 26,000 32,000 37,000
Capacity Range Btu/h 8,000-20,000 12,000-28,000 12,000-34,000 12,000-38,000
Heating at 47º F *2
Total Input W 2,130 2,570 3,660 3,610
HSPF (Region IV) Btu/h/W 8.3 8.5 8.3
Capacity Btu/h 13,000 16,000 23,000 25,000
Heating at 17º F *3
Total Input W 1,670 2,200 3,050 3,070
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208-230V *4
Indoor - Outdoor S1-S2 AC 208/230V
Indoor - Outdoor S2-S3 DC24V
Voltage
Indoor - Remote Controller DC12V : Wired Type (GA/FA)
Indoor - Remote Controller Wireless Type (GAL/FAL)
MCA A 1
Fan Motor F.L.A. 0.33 0.43 0.52
Fan Motor Output W 30 45 70
Airflow (Lo-M1-M2-Hi) or DRY (CFM) 320-350-390-425 530-705 780-990
(Lo-Hi) WET (CFM) 290-315-350-380 480-635 700-890
Sound Pressure Level
dB(A) 36-38-41-43 39-45 46-49
Indoor Unit (Lo-M1-M2-Hi) or (Lo-Hi)
External Finish Color Munsell No. 0.70Y 8.59/0.97 Munsell No. 3.4Y 7.7/0.8
W: In. 39 55-1/8 66-1/8
Dimension Unit D: In. 9-1/4
H: In. 13-3/8
Weight Unit Lbs. 35 53 62
Field Drainpipe Size I.D. In. 13/16
MCA A 13 18 25
MOCP A 20 30 40
Fan Motor F.L.A. 0.35 0.75
Fan Motor Output W 40 75
Model (Type) DC INVERTER-driven Twin Rotary
Compressor R.L.A. 12
L.R.A. 14 17.5
Airflow CFM 1,200 1,940
Refrigerant Control Linear Expansion Valve
Outdoor Unit Defrost Method Reverse Cycle
Sound Pressure Level 46 48
(Cooling) *1
dB(A)
Sound Pressure Level
47 50
(Heating) *2
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 31-1/2 37-3/8
Dimensions D: In. 13 + 7/8 13 + 1-3/16
H: In. 23-5/8 37-1/8
Weight Lbs. 99 165
Remote Controller Type GA/FA: Wired Controller; GAL/FAL: Wireless Controller (Located with Indoor Unit)
Type R410A
Refrigerant Charge Lbs., Oz. 3, 12 6
Oil Type (Fl. Oz.) MEL56 (20) MEL56 (28)
Gas Side O.D. 1/2 5/8
Refrigerant Pipe In.
Liquid Side O.D. 1/4 3/8
Height Difference (Max.) Ft. 100
Refrigerant Pipe Length
Length (Max.) 100 165
Connection Method Indoor/Outdoor Flared/Flared
NOTES: Test conditions are based on ARI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8.3º C), W.B. 15º F (-9º C).
*4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.
26
ceiling-recessed series
PLA PL A I n d o o r U n i t
(Same indoor unit is used for both
cooling and heat pump systems)
12,000 to 42,000
Btu/h Capacity
If there’s at least a foot of space above
your ceiling, the PLA-Series is for you.
These models combine powerful cooling
and heating in an elegant cassette design Auto Fan Speed Feature
that recesses into the ceiling. When
Choose from four set fan speeds or auto
installed, the attractive, low-profile grille is
fan speed to ensure faster achievement of
all you see. With its ventilation air intake
room temperature. Auto fan speed mode
capability and four-way discharge airflow,
allows the fan to adjust its speed based
the PLA-Series gives you plenty of com-
on the degree of differential between
fortable airflow options. These units even
set-point and room temperature.
contain branch duct knockouts for either Auto Fan Speed Mode
27
INVERTER
PLA COOLING-ONLY
(PLA-A36BA Model Shown P-Series Specifications
with optional I-SEE™ sensor)
BS = Seacoast Protection
Indoor Unit PLA-A12BA PLA-A18BA PLA-A24BA PLA-A30BA PLA-A36BA PLA-A42BA
Model Name PUY-A12NHA PUY-A18NHA PUY-A24NHA PUY-A30NHA PUY-A36NHA PUY-A42NHA
Outdoor Unit
PUY-A12NHA-BS PUY-A18NHA-BS PUY-A24NHA-BS PUY-A30NHA-BS PUY-A36NHA-BS PUY-A42NHA-BS
Rated Capacity Btu/h 12,000 18,000 24,000 30,000 35,000 42,000
Capacity Range Btu/h 6,000-12,000 8,000-18,000 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000
Total Input W 1,260 1,940 2,500 4,100 4,500 4,600
Cooling *1
Energy Efficiency SEER 13.5 14.2 13.6 14.2 14.4
Moisture Removal Pints/h 1.7 3.0 5.1 7.2 8.1 10.9
Sensible Heat Factor 0.84 0.81 0.76 0.73 0.74 0.71
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208-230V *2
Indoor - Outdoor S1-S2 AC 208/230V
Voltage Indoor - Outdoor S2-S3 DC24V
Indoor - Remote Controller DC12V : Wired Type
MCA A 1 2
Fan Motor F.L.A. 0.51 1.00
Fan Motor Output W 50 120
DRY (CFM) 390-420-460-530 420-490-570-640 490-570-640-740 710-810-920-1,060 780-880-990-1,090
Airflow (Lo-M1-M2-Hi)
WET (CFM) 350-390-420-490 390-460-530-600 460-530-600-710 670-770-880-1,030 740-850-950-1,060
External Pressure Pa 0
Sound Pressure Level
dB(A) 27-28-29-31 28-29-31-32 28-30-32-34 32-34-37-40 34-36-39-41
Indoor Unit (Lo-M1-M2-Hi)
External Finish Color (Panel) Munsell No. 6.4Y 8.9/0.4
W: In. 33-1/16 (37-3/8)
Dimension Unit (Panel) D: In. 33-1/16 (37-3/8)
H: In. 10-3/16 (1-3/8) 11-3/4 (1-3/8)
Weight Unit (Panel) Lbs. 49 (13) 51 (13) 55 (13)
Drain Lift Mechanism
H: In. 33-7/16
(included)
Field Drainpipe Size O.D. In. 1-1/4
MCA A 13 18 25 26
MOCP A 15 20 30 40
Fan Motor F.L.A. 0.35 0.75 0.4 + 0.4
Fan Motor Output W 40 75 86 + 86
Model INVERTER-driven
DC INVERTER-driven Twin Rotary
(Type) Scroll
Compressor
R.L.A. 12 20
L.R.A. 14 17.5 27.5
Outdoor Unit Airflow CFM 1,200 1,940 3,530
Refrigerant Control Linear Expansion Valve
Sound Pressure Level
dB(A) 46 48 51
(Cooling) *1
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 31-1/2 37-3/8
Dimensions D: In. 13 + 7/8 13 + 1-3/16
H: In. 23-5/8 37-1/8 53-1/8
Weight Lbs. 90 97 163 258
Remote Controller Type Wired Remote Controller Packaged with Grille
Type R410A
Refrigerant Charge Lbs., Oz. 2, 14 3, 12 6 10
Oil Type (Fl. Oz.) MEL56 (20) MEL56 (28) FV50S (45)
Gas Side O.D. 1/2 5/8
In.
Liquid Side O.D. 1/4 3/8
Refrigerant Pipe
Height Difference (Max.) 100
Ft.
Length (Max.) 100 165
Connection
Indoor/Outdoor Flared/Flared
Method
NOTES: Test conditions are based on ARI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.
28
INVERTER
PLA heat pump
(PLA-A36BA Model Shown
with optional I-SEE™ sensor)
P-Series Specifications
BS = Seacoast Protection
Indoor Unit PLA-A18BA PLA-A24BA PLA-A30BA PLA-A36BA PLA-A42BA
Model Name PUZ-A18NHA PUZ-A24NHA PUZ-A30NHA PUZ-A36NHA PUZ-A42NHA
Outdoor Unit
PUZ-A18NHA-BS PUZ-A24NHA-BS PUZ-A30NHA-BS PUZ-A36NHA-BS PUZ-A42NHA-BS
Rated Capacity Btu/h 18,000 24,000 30,000 35,000 42,000
Capacity Range Btu/h 8,000-18,000 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000
Total Input W 1,940 2,500 4,100 4,500 4,600
Cooling *1
Energy Efficiency SEER 14.2 13.6 14.2 14.4
Moisture Removal Pints/h 3.0 5.1 7.2 8.1 10.9
Sensible Heat Factor 0.81 0.76 0.73 0.74 0.71
Rated Capacity Btu/h 19,000 26,000 32,000 37,000 45,000
Capacity Range Btu/h 8,000-20,000 12,000-28,000 12,000-34,000 12,000-38,000 18,000-48,000
Heating at 47º F *2
Total Input W 1,900 2,570 3,370 3,300 4,450
HSPF (Region IV) Btu/h/W 9.8 8.5 8.7 9.3
Capacity Btu/h 13,000 16,000 23,000 25,000 30,000
Heating at 17º F *3
Total Input W 1,590 2,200 3,050 3,070 4,300
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Indoor - Outdoor S1-S2 AC 208-230V
Voltage Indoor - Outdoor S2-S3 DC24V
Indoor - Remote Controller DC12V : Wired Type
MCA A 1 2
Fan Motor F.L.A. 0.51 1.00
Fan Motor Output W 50 120
DRY (CFM) 420-490-570-640 490-570-640-740 710-810-920-1,060 780-880-990-1,090
Airflow (Lo-M1-M2-Hi)
WET (CFM) 390-460-530-600 460-530-600-710 670-770-880-1,030 740-850-950-1,060
External Pressure Pa 0
Sound Pressure Level
dB(A) 28-29-31-32 28-30-32-34 32-34-37-40 34-36-39-41
(Lo-M1-M2-Hi)
Indoor Unit
External Finish Color (Panel) Munsell No. 6.4Y 8.9/0.4
W: In. 33-1/16 (37-3/8)
Dimension Unit (Panel) D: In. 33-1/16 (37-3/8)
H: In. 10-3/16 (1-3/8) 11-3/4 (1-3/8)
Weight Unit (Panel) Lbs. 49 (13) 51 (13) 55 (13)
Drain Lift Mechanism
H: In. 33-7/16
(included)
Field Drainpipe Size O.D. In. 1-1/4
MCA A 13 18 25 26
MOCP A 15 30 40
Fan Motor F.L.A. 0.35 0.75 0.4 + 0.4
Fan Motor Output W 40 75 86 + 86
INVERTER-driven
Model (Type) DC INVERTER-driven Twin Rotary
Scroll
Compressor
R.L.A 12 20
L.R.A. 14 17.5 27.5
Airflow CFM 1,200 1,940 3,530
Refrigerant Control Linear Expansion Valve
Outdoor Unit
Defrost Method Reverse Cycle
Sound Pressure Level
dB(A) 46 48 51
(Cooling) *1
Sound Pressure Level
dB(A) 47 50 55
(Heating) *2
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 31-1/2 37-3/8
Dimensions D: In. 13 + 7/8 13 + 1-3/16
H: In. 23-5/8 37-1/8 53-1/8
Weight Lbs. 99 165 260
Remote Controller Type Wired Remote Controller Packaged with Grille
Type R410A
Refrigerant Charge Lbs., Oz. 3, 12 6 10
Oil Type (Fl. Oz.) MEL56 (20) MEL56 (28) FV50S (45)
Gas Side O.D. 1/2 5/8
In.
Refrigerant Pipe Liquid Side O.D. 1/4 3/8
Height Difference (Max.) 100
Ft.
Length (Max.) 100 165
Connection Method Indoor/Outdoor Flared/Flared
NOTES: Test conditions are based on ARI 210/240. *3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C). *4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Specifications are subject to change without notice.
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6.1º C). LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.
29
PCA
CEILING-SUSPENDED series
24,000 to 42,000 Btu/h Capacity
30
(PCA-A36GA Model Shown)
INVERTER
PCA COOLING-ONLY
P-Series Specifications
BS = Seacoast Protection
Indoor Unit PCA-A24GA PCA-A30GA PCA-A36GA PCA-A42GA
Model Name PUY-A24NHA PUY-A30NHA PUY-A36NHA PUY-A42NHA
Outdoor Unit
PUY-A24NHA-BS PUY-A30NHA-BS PUY-A36NHA-BS PUY-A42NHA-BS
Rated Capacity Btu/h 24,000 30,000 35,000 42,000
Capacity Range Btu/h 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000
Total Input W 2,500 4,100 4,630 5,070
Cooling *1
Energy Efficiency SEER 13.4 13.0 13.1 13.8
Moisture Removal Pints/h 5.4 8.3 8.2 11.7
Sensible Heat Factor 0.75 0.69 0.74 0.69
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208-230V *2
Indoor - Outdoor S1-S2 AC 208/230V
Voltage Indoor - Outdoor S2-S3 DC24V
Indoor - Remote Controller DC12V : Wired Type
MCA A 1
Fan Motor F.L.A. 0.53 0.69
Fan Motor Output W 70 90
DRY (CFM) 495-530-565-635 705-740-810-880
Airflow (Lo-M1-M2-Hi)
WET (CFM) 445-480-510-570 635-670-730-790
Sound Pressure Level
dB(A) 37-39-41-43 40-41-43-45
Indoor Unit (Lo-M1-M2-Hi)
External Finish Color Munsell No. 0.70Y 8.59/0.97
W: In. 51-9/16
Dimension Unit D: In. 26-3/4
H: In. 8-5/16 10-5/8
Weight Unit Lbs. 75 82
Field Drainpipe Size O.D. In. 1
MCA A 18 25 26
MOCP A 30 40
Fan Motor F.L.A. 0.75 0.4 + 0.4
Fan Motor Output W 75 86 + 86
INVERTER-driven
Model (Type) DC INVERTER-driven Twin Rotary
Scroll
Compressor R.L.A. 12 20
L.R.A. 14 17.5 27.5
Outdoor Unit Airflow CFM 1,940 3,530
Refrigerant Control Linear Expansion Valve
Sound Pressure Level (Cooling) *1 dB(A) 48 51
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 37-3/8
Dimensions D: In. 13 + 1-3/16
H: In. 37-1/8 53-1/8
Weight Lbs. 163 258
Remote Controller Type Wired Remote Controller (Located with Indoor Unit)
Type R410A
Refrigerant Charge Lbs. 6 10
Oil Type (Fl. Oz.) MEL56 (28) FV50S (45)
Gas Side O.D. 5/8
In.
Refrigerant Pipe Liquid Side O.D. 3/8
Height Difference (Max.) Ft. 100
Length (Max.) 165
Connection Method Indoor/Outdoor Flared/Flared
31
(PCA-A36GA Model Shown)
INVERTER
PCA Heat Pump
P-Series Specifications
BS = Seacoast Protection
Indoor Unit PCA-A24GA PCA-A30GA PCA-A36GA PCA-A42GA
Model Name PUZ-A24NHA PUZ-A30NHA PUZ-A36NHA PUZ-A42NHA
Outdoor Unit
PUZ-A24NHA-BS PUZ-A30NHA-BS PUZ-A36NHA-BS PUZ-A42NHA-BS
Rated Capacity Btu/h 24,000 30,000 35,000 42,000
Capacity Range Btu/h 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000
Total Input W 2,500 4,100 4,630 5,070
Cooling *1
Energy Efficiency SEER 13.4 13 13.1 13.8
Moisture Removal Pints/h 5.4 8.3 8.2 11.7
Sensible Heat Factor 0.75 0.69 0.74 0.69
Rated Capacity Btu/h 26,000 32,000 37,000 45,000
Capacity Range Btu/h 12,000-28,000 12,000-34,000 12,000-38,000 18,000-48,000
Heating at 47º F *2
Total Input W 2,570 3,390 3,490 4,850
HSPF (Region IV) Btu/h/W 8.5 8.3 8.5
Capacity Btu/h 16,000 23,000 25,000 30,000
Heating at 17º F *3
Total Input W 2,200 3,050 3,070 4,300
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Indoor - Outdoor S1-S2 AC 208-230V
Voltage Indoor - Outdoor S2-S3 DC24V
Indoor - Remote Controller DC12V : Wired Type
MCA A 1
Fan Motor F.L.A. 0.53 0.69
Fan Motor Output W 70 90
DRY (CFM) 495-530-565-635 705-740-810-880
Airflow (Lo-M1-M2-Hi)
WET (CFM) 445-480-510-570 635-670-730-790
Sound Level
dB(A) 37-39-41-43 40-41-43-45
Indoor Unit (Lo-M1-M2-Hi)
External Finish Color Munsell No. 0.70Y 8.59/0.97
W: In. 51-9/16
Dimension Unit D: In. 26-3/4
H: In. 8-5/16 10-5/8
Weight Unit Lbs. 75 82
Field Drainpipe Size O.D. In. 1
MCA A 18 25 26
MOCP A 30 40
Fan Motor F.L.A. 0.75 0.4 + 0.4
Fan Motor Output W 75 86 + 86
INVERTER-driven
Model (Type) DC INVERTER-driven Twin Rotary
Scroll
Compressor
R.L.A. 12 20
L.R.A. 14 17.5 27.5
Airflow CFM 1,940 3,530
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Level at Cooling *1 dB(A) 48 51
Sound Level at Heating *2 dB(A) 50 55
External Finish Color Munsell No. 3Y 7.8/1.1
W: In. 37-3/8
Dimensions D: In. 13 + 1-3/16
H: In. 37-1/8 53-1/8
Weight Lbs. 165 260
Remote Controller Type Wired Remote Controller (Located with Indoor Unit)
Type R410A
Refrigerant Charge Lbs. 6 10
Oil Type (Fl. Oz.) MEL56 (28) FV50S (45)
Gas Side O.D. 5/8
In.
Liquid Side O.D. 3/8
Refrigerant Pipe
Height Difference (Max.) Ft. 100
Length (Max.) 165
Connection Method Indoor/Outdoor Flared/Flared
NOTES: Test conditions are based on ARI 210/240.
*1 Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3 Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C); Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4 Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY Six-year warranty on compressor. One-year warranty on parts.
32
MS/MU,MSY/MUY,MSZ/MUZ/MXZ RATING CONDITIONS REFRIGERANT LINE LENGTH FLARE/FLARE
INDOOR INTAKE AIR OUTDOOR INTAKE AIR Max. Max.
TEMPERATURE TEMPERATURE Indoor Unit Outdoor Unit Length Height
in feet in feet
95º F D.B. (MS/MSY/MSZ), MS-A09WA MU-A09WA 65 35
90º F D.B. (MSY/MSZ-D/FD),
MAXIMUM 115º F D.B. MS-A12WA MU-A12WA 65 35
71º F W.B. (MS/MSY/MSZ),
COOLING 73º F W.B. (MSY/MSZ-D/FD) MSY-A15NA MUY-A15NA 65 40
MSY-A17NA MUY-A17NA 65 40
67º F D.B. (MU),
MINIMUM 67º F D.B., 57º F W.B. MSY-A24NA MUY-A24NA 100 50
14º F D.B. (MUY(Z), MXZ)
MAXIMUM 80º F D.B., 67º F W.B. 75º F D.B., 65º F W.B. MSZ-A09NA MUZ-A09NA 65 40
MSZ-A12NA MUZ-A12NA 65 40
HEATING 14º F D.B., 13º F W.B. (MUZ),
MINIMUM 70º F D.B., 60º F W.B. MSZ-A15NA MUZ-A15NA 65 40
12º F W.B. (MXZ)
MSZ-A17NA MUZ-A17NA 65 40
* MU units operate at intake air temperature down to 10º F with the addition of an ICM-326HM-1 low temperature control.
MSZ-A24NA MUZ-A24NA 100 50
33
OPTIONAL ACCESSORIES
PART NUMBER USE WITH DESCRIPTION
Controls Options
MAC-397IF-E M-Series Inverter Units MA and contact terminal interface
MAC-399IF-E M-Series Inverter Units M-NET control adapter for Mr. Slim MSY and MSZ models
PAC-725AD P-Series Connector for CN51/multiple remote controller adapter and duct fan controller
PAC-715AD P-Series Connector for CN32 (For remote ON/OFF)
PAC-SE41TS-E P-Series Remote temperature sensor for indoor units
PAC-SA1ME-E PLA-ABA i-see™ sensor corner panel for PLA-ABA indoor units
PAC-SF40RM-E P-Series Remote operation adapter: display and ON/OFF
PAC-SF80MA-E P-Series M-NET control adapter for Mr. Slim PUY-A, PUZ-A, and PUZ-HA Models
PAC-SK52ST P-Series Control / service tool
PAR-21MAA-G Use for wired M-Series Controller Deluxe MA remote controller (Requires MAC-397IF-E)
PAR-SL99U-E PCA Wireless remote controller kit for PCA suspended units
PAR-FA32MA-E PLA-ABA Wireless remote controller for PLA-ABA units (Requires signal receiver PAR-SA9FA-E)
PAR-SA9FA-E PLA-ABA Wireless signal receiver for PLA-ABA units (For PAR-FA32MA-E controller)
PZ-41SLB-E Lossnay® Lossnay ERV remote controller for LGH ERV control
Low Ambient
WB-PA1 P-Series Wind baffle (1 piece) PUY/Z-A12/A18
WB-PA2 P-Series Wind baffle (1 piece) PUY/Z-A24/A30/A36/A42 (42 installation requires 2 pieces); PUZ-HA36NA (Requires 2 pieces)
ICM-326HM-1 M-Series Non-Inverter units Low ambient head pressure controller
Filters
MAC-2300FT M-Series Indoor Unit - A24 Anti-allergy enzyme filter
MAC-415FT M-Series Indoor Unit - A09/A12/A15/A17 Anti-allergy enzyme filter
MAC-418FT MSZ-FD09/12 Anti-allergy enzyme filter
MAC-308FT MSZ-FD09/12 Platinum deodorizing filter
MAC-1415FT-E M-Series Indoor Unit - D30/36 Anti-allergy enzyme filter
PAC-SE81KF-E PCA High-efficiency (MERV 10) filter element
PAC-SH59KF-E PLA-ABA High-efficiency (MERV 10) filter element (Requires PAC-SH53TM-E multi-function casement)
Pumps
SI1730-230 P-Series Mini-condensation pump: 230V
SI3100-115 MS-Series Mini-condensation pump: 115V
SI3100-230 MSY/Z-Series Mini-condensation pump: 230V
Miscellaneous
TAZ-MS303 M-Series and P-Series Three-pole disconnect switch; 30A, 600V; turns off power between indoor and outdoor units
CWMB1 MU and PU outdoor units Condensing unit wall mounting brackets: painted steel
PAC-SH53TM-E PLA-ABA Multi-function casement (High-efficiency filter element not included)
PAC-SH51SP-E PLA-ABA Air outlet shutter plates (1 set = 2 pieces)
PAC-SG58SG-E P-Series Air outlet guide (1 piece) PUY/Z-A12/A18
PAC-SG59SG-E P-Series Air outlet guide (1 piece) PUY/Z-A24/A30/A36/A42 (42 installation requires 2 pieces); PUZ-HA36NA (Requires 2 pieces)
PAC-SG61DS-E P-Series Drain socket
MAC-851DS MUZ-FD09/12 Drain socket
MAC-811DS MUY(Z)-D30/36 Drain socket assembly
PAC-SG63DP-E PUY(Z)-A12/18 Drain pan
PAC-SG64DP-E PUY(Z)-A24/30/36/42 and PUZ-HA36 Drain pan
RCMKP1CB M and P Series Wireless Lockdown bracket for wireless remote controller
ULTRILITE1 All M-Series and PUZ(Y)-A12/18 Condensing unit mounting pad: 16" x 36" x 3"
ULTRILITE2 PUY(Z)-A24/30/36/42; PUZ-HA36 Condensing unit mounting pad: 24" x 42" x 3"
Port Adapters
MAC-A454JP-E MXZ-Series Adapter: 3/8" x 1/2"
MAC-A455JP-E MXZ-Series Adapter: 1/2" x 3/8"
MAC-A456JP-E MXZ-Series Adapter: 1/2" x 5/8"
PAC-493PI MXZ-Series Adapter: 1/4" x 5/8"
PAC-SG76RJ-E MXZ-Series Adapter: 3/8" x 5/8"
MSDD-50SR-E P-Series Distribution pipe
PAC-SC84PI-E PKA-Series (A24/30/36/42) L-connector pipe (for left-side piping)
34
LLineset
ine - Hide
TM
Cover System
Put a professional finish on air conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects linesets, drainlines, and wiring.
• Available in four sizes: 2-1/4”, 3”, 4”, and 6” tubes.
• Snap-on covers and a full selection of couplings,
elbows, T-joints, caps, and more for any application,
complex or simple.
• High-quality PVC with UV inhibitors for outdoor
service in all weather conditions.
• Can be painted with most house paints to match
exterior decors.
• Not just for HVAC. Hide any exterior cabling, piping,
or wiring.
• Use it indoors, too! Meets UL94v-0 for interior
applications.
Download a brochure at www.mrslim.com to find out
more information.
Suwanee, GA 30024
Phone: 888-467-7546 Fax: 800-658-1458
EC 97J1132
©2008 Mitsubishi Electric & Electronics USA, Inc. Mr Slim is a registered trademark, and H2i
is a trademark of Mitsubishi Electric. The three-diamond logo is a registered logo of Mitsubishi
Electric Corporation.
*Hyper-Heating technology Patent Pending.
See complete warranty for terms, conditions and limitations. A copy is available from Mitsubishi Electric.